National Repository of Grey Literature 4 records found  Search took 0.01 seconds. 
Testing of transformer protection
Kulač, Ivan ; Novotný, Jan (referee) ; Orságová, Jaroslava (advisor)
The main theme of my Bachelor thesis was protection of the transformer, measured case was orient to differential protection of the transformer, functions, stabilization and release characteristic. The proposed method of testing module SPCD3D53 differential protection SPAD 346C which was made by ABB. Setting of release characteristics on the protection were made for real power transformers. Testing device OMICRON CMC 256 plus was used to measurement, which was same as protection connected to personal computer. All the PC’s settings operations were realized by recommended software. The measurements were made for three cases, when differential current was in one, two or three phases. Results of measurement are mentioned in tables and graph.
Differential Protection for Power Transformer
Bukvišová, Zuzana ; Wasserbauer, Vojtěch (referee) ; Orságová, Jaroslava (advisor)
This thesis explores power transformer protection and focuses on differential protection. It attempts to explain its principles and operating characteristic settings. The measurement was executed on devices SPAD 346 C and REF542plus, which can be used for differential protection. At the end, there is a comparison of results of operating characteristic measurement on both devices. Their function was tested at different cases, specifically when the differential current occurs in all phases or just one. The thesis includes a comparison of reaction times under fast increase of current. OMICRON CMC 256 plus was used as the test device. The data obtained by the measurement are processed in tables and charts.
Differential Protection for Power Transformer
Bukvišová, Zuzana ; Wasserbauer, Vojtěch (referee) ; Orságová, Jaroslava (advisor)
This thesis explores power transformer protection and focuses on differential protection. It attempts to explain its principles and operating characteristic settings. The measurement was executed on devices SPAD 346 C and REF542plus, which can be used for differential protection. At the end, there is a comparison of results of operating characteristic measurement on both devices. Their function was tested at different cases, specifically when the differential current occurs in all phases or just one. The thesis includes a comparison of reaction times under fast increase of current. OMICRON CMC 256 plus was used as the test device. The data obtained by the measurement are processed in tables and charts.
Testing of transformer protection
Kulač, Ivan ; Novotný, Jan (referee) ; Orságová, Jaroslava (advisor)
The main theme of my Bachelor thesis was protection of the transformer, measured case was orient to differential protection of the transformer, functions, stabilization and release characteristic. The proposed method of testing module SPCD3D53 differential protection SPAD 346C which was made by ABB. Setting of release characteristics on the protection were made for real power transformers. Testing device OMICRON CMC 256 plus was used to measurement, which was same as protection connected to personal computer. All the PC’s settings operations were realized by recommended software. The measurements were made for three cases, when differential current was in one, two or three phases. Results of measurement are mentioned in tables and graph.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.