National Repository of Grey Literature 10 records found  Search took 0.01 seconds. 
The influence of eye movement on postural stability
Míková, Monika ; Kolářová, Jana (referee) ; Němcová, Andrea (advisor)
The Bachelor thesis discusses the influence of eye movement on postural stability. Thesis includes problematics of postural stability, physiology of sight, oculomotoric and measuring of eye movement via electrooculography method. Postural stability is measured with Wii Balance Board, which records antero-posterior and medio-lateral displacement of the COP position. Eye movements are measured with Biopac system, its output is EOG. Ten people were involved in this study. Parameters were calculated from stabilometric signal and from EOG. Results were procesed statistically.
Transcutaneous electrogastrography
Davidová, Lenka ; Závodná, Eva (referee) ; Nováková, Zuzana (advisor)
The aim of this thesis is to introduce the physiology and pathophysiology of the gastrointestinal tract, with functional parameters and appropriate diagnostics. The thesis also deals with transcutaneous electrogastrography devices and presents a suggestion of a measurement protocol which would involve a group of volunteers in fasting and postprandial states. The theoretical part describes the function of the gastrointestinal tract, detailing the analysis of gastric myoelectric activity and gastric motility. It also outlines technical and formal aspects of the parameters, artefacts and subsequent data analysis. In the practical part, a program is designed and implemented in the Matlab computing environment for the analysis of EGG recordings. Furthermore, differences between parameters in fasting and postprandial states are evaluated.
Measurement and analysis of cardiovascular parameters
Filipová, Petra ; Smital, Lukáš (referee) ; Kratochvíla, Jiří (advisor)
This bachelor´s thesis illustrates the basic diagnostic procedures for ECG analysis in clinical practice. It contains the verification of statistical hypotheses, automatic detection of the RR intervals using three different QRS detectors and heart rate from the ECG und other analyses in time and frequency domain. The validation of detection efficiency is investigated. Heart rate variability analyses are shown in time and frequency domain too. Analyses are done in Matlab, the graphical interface in Maltab GUIDE was done too and includes all of the created functions in time and frequency domain. For the purpose of evaluation methods the real data were measured according to the created acquisition protocol.
Scanning a analysing of heart electrical activity and blood pressure before and after the load
Vích, Daniel ; Kolářová, Jana (referee) ; Kratochvíla, Jiří (advisor)
The aim of bachelor’s thesis is familiarization with anatomy and physiology of heart, with setting to electrical activity, scanning EKG before and after the load with Biopac system, scanning of blood pressure before and after the load with auscultation, statistical analysis of acquired data and presentation of measured data in graphical interface Guide of Matlab system. According to the protocol of measurement, scanning of heart electrical activity with the Biopac system, and scanning of blood pressure, with auscultation, was realized before and after the load. Measured data was statistically analyzed with t-test to verify hypothesis, that there is an influence of the load on the watched parameters, and to show the process of statistical verification. Application of this method assumes normal distribution of data, that’s why data was at first tested by Chi-squared and Kolmogorov-Smirnov test to verify their normal distribution. In the next step data was imported into Matlab system. The presentation of measured data is realized in graphic interface Guide. The program contains time domain and spectral analysis, automatic detection of heart rate and analysis of heart rate variability.
Acceleration and motion of upper limbs
Novotný, Adam ; Kolář, Radim (referee) ; Kolářová, Jana (advisor)
Purpose of this work is mainly the description of electrical plots in skeletal muscles and secondarily experimental verification and description of methods connected with measuring and evaulating biosignals. The theoretical presentation of muscle physiology facts is supplemented with an experiment using pair t-test, which describes procedures leading to evaluating particular hypotheses (the measured muscle is biceps brachii). In this work, the biosignal is an EMG signal, thus the electrical activity of muscle. Therefore, the main objective of this work is not only about using EMG as an examination method, but also about showing a complex view at the recording, processing and evaluating of EMG signal. These facts are supplemented with programm application which is showing the way working with EMG signals and also the possibilities of algorithm development in such signals.
The influence of eye movement on postural stability
Míková, Monika ; Kolářová, Jana (referee) ; Němcová, Andrea (advisor)
The Bachelor thesis discusses the influence of eye movement on postural stability. Thesis includes problematics of postural stability, physiology of sight, oculomotoric and measuring of eye movement via electrooculography method. Postural stability is measured with Wii Balance Board, which records antero-posterior and medio-lateral displacement of the COP position. Eye movements are measured with Biopac system, its output is EOG. Ten people were involved in this study. Parameters were calculated from stabilometric signal and from EOG. Results were procesed statistically.
Transcutaneous electrogastrography
Davidová, Lenka ; Závodná, Eva (referee) ; Nováková, Zuzana (advisor)
The aim of this thesis is to introduce the physiology and pathophysiology of the gastrointestinal tract, with functional parameters and appropriate diagnostics. The thesis also deals with transcutaneous electrogastrography devices and presents a suggestion of a measurement protocol which would involve a group of volunteers in fasting and postprandial states. The theoretical part describes the function of the gastrointestinal tract, detailing the analysis of gastric myoelectric activity and gastric motility. It also outlines technical and formal aspects of the parameters, artefacts and subsequent data analysis. In the practical part, a program is designed and implemented in the Matlab computing environment for the analysis of EGG recordings. Furthermore, differences between parameters in fasting and postprandial states are evaluated.
Measurement and analysis of cardiovascular parameters
Filipová, Petra ; Smital, Lukáš (referee) ; Kratochvíla, Jiří (advisor)
This bachelor´s thesis illustrates the basic diagnostic procedures for ECG analysis in clinical practice. It contains the verification of statistical hypotheses, automatic detection of the RR intervals using three different QRS detectors and heart rate from the ECG und other analyses in time and frequency domain. The validation of detection efficiency is investigated. Heart rate variability analyses are shown in time and frequency domain too. Analyses are done in Matlab, the graphical interface in Maltab GUIDE was done too and includes all of the created functions in time and frequency domain. For the purpose of evaluation methods the real data were measured according to the created acquisition protocol.
Scanning a analysing of heart electrical activity and blood pressure before and after the load
Vích, Daniel ; Kolářová, Jana (referee) ; Kratochvíla, Jiří (advisor)
The aim of bachelor’s thesis is familiarization with anatomy and physiology of heart, with setting to electrical activity, scanning EKG before and after the load with Biopac system, scanning of blood pressure before and after the load with auscultation, statistical analysis of acquired data and presentation of measured data in graphical interface Guide of Matlab system. According to the protocol of measurement, scanning of heart electrical activity with the Biopac system, and scanning of blood pressure, with auscultation, was realized before and after the load. Measured data was statistically analyzed with t-test to verify hypothesis, that there is an influence of the load on the watched parameters, and to show the process of statistical verification. Application of this method assumes normal distribution of data, that’s why data was at first tested by Chi-squared and Kolmogorov-Smirnov test to verify their normal distribution. In the next step data was imported into Matlab system. The presentation of measured data is realized in graphic interface Guide. The program contains time domain and spectral analysis, automatic detection of heart rate and analysis of heart rate variability.
Acceleration and motion of upper limbs
Novotný, Adam ; Kolář, Radim (referee) ; Kolářová, Jana (advisor)
Purpose of this work is mainly the description of electrical plots in skeletal muscles and secondarily experimental verification and description of methods connected with measuring and evaulating biosignals. The theoretical presentation of muscle physiology facts is supplemented with an experiment using pair t-test, which describes procedures leading to evaluating particular hypotheses (the measured muscle is biceps brachii). In this work, the biosignal is an EMG signal, thus the electrical activity of muscle. Therefore, the main objective of this work is not only about using EMG as an examination method, but also about showing a complex view at the recording, processing and evaluating of EMG signal. These facts are supplemented with programm application which is showing the way working with EMG signals and also the possibilities of algorithm development in such signals.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.