Protection setting concept for given MV substation
Váhala, Václav ; Holub, Jiří (referee) ; Topolánek, David (advisor)
The thesis is focused on the protection concept for medium voltage substation. The first theoretical part of thesis describes given medium voltage substation. Substation consists of two incoming feeders and six outgoing feeders. Due to the size of the substation was selected one outgoing feeder which is the subject of description and protection concept. Next part of the thesis is a description of the protective functions used to protect the elements in the selected feeder. This part contains a detailed description of the function and setting options for protection. The main part of the thesis describes calculation of specific protection functions and consequently with secondary testing of protective functions. Tests were performed on protective functions in the digital protections REF615 and REM620. The final part of the thesis deals with the evaluation of the secondary test results and verification saturation of the specified current transformers.
Design of protection system using an sensor technology in MV substation
Strapko, Miroslav ; Prokop, Václav (referee) ; Topolánek, David (advisor)
Master's thesis deals with use of electronic instrument transformers (sensors) in the protection system in medium-voltage substation. Substation consists of 2 incoming feeders, 2 outgoing feeders for motors, 2 outgoing feeders for power transformers, measuring, bus coupler and bus riser feeder. Incoming feeders are connected to distribution system E.ON by cable lines which were proposed. Protected machines (power transformers and motors with rated power) are connected to switchgear panels of UniGear ZS1 type by cable lines too. Proposed protection system is based on the short-circuit conditions, standard CSN 33 3051 recommendations as well as theoretical backgrounds acquired from technical papers and other publicated literature according to the bibliography. For selected protection functions are defined their parameters. Control, monitoring and protection functions provides REF 542plus relay. Consequently, secondary tests which are part of the commissioning, are given in the practical part of thesis. Secondary tests were performed by relay test system FREJA 300 by Megger. Results of tests are displayed in tripping characteristics.
Protection setting concept for given MV substation
Váhala, Václav ; Holub, Jiří (referee) ; Topolánek, David (advisor)
The thesis is focused on the protection concept for medium voltage substation. The first theoretical part of thesis describes given medium voltage substation. Substation consists of two incoming feeders and six outgoing feeders. Due to the size of the substation was selected one outgoing feeder which is the subject of description and protection concept. Next part of the thesis is a description of the protective functions used to protect the elements in the selected feeder. This part contains a detailed description of the function and setting options for protection. The main part of the thesis describes calculation of specific protection functions and consequently with secondary testing of protective functions. Tests were performed on protective functions in the digital protections REF615 and REM620. The final part of the thesis deals with the evaluation of the secondary test results and verification saturation of the specified current transformers.
Design of protection system using an sensor technology in MV substation
Strapko, Miroslav ; Prokop, Václav (referee) ; Topolánek, David (advisor)
Master's thesis deals with use of electronic instrument transformers (sensors) in the protection system in medium-voltage substation. Substation consists of 2 incoming feeders, 2 outgoing feeders for motors, 2 outgoing feeders for power transformers, measuring, bus coupler and bus riser feeder. Incoming feeders are connected to distribution system E.ON by cable lines which were proposed. Protected machines (power transformers and motors with rated power) are connected to switchgear panels of UniGear ZS1 type by cable lines too. Proposed protection system is based on the short-circuit conditions, standard CSN 33 3051 recommendations as well as theoretical backgrounds acquired from technical papers and other publicated literature according to the bibliography. For selected protection functions are defined their parameters. Control, monitoring and protection functions provides REF 542plus relay. Consequently, secondary tests which are part of the commissioning, are given in the practical part of thesis. Secondary tests were performed by relay test system FREJA 300 by Megger. Results of tests are displayed in tripping characteristics.