Air tightness of building structures and critical details
Vávra, Petr ; Tichomirov,, Vladimír (referee) ; Bečkovský, David (advisor)
In thesis is dealt with problematic of how the value of air permeability may be affected by properties for water vapour diffusion with regard to OSB material There were chosen two main brands of OSB at Czech trade market Two specimens of OSB with different thickness were chosen for each brand. As a first the specimens were tested for air tightness to work out a value of air permeability for each specimen. Afterwords, the testing was conducted for gaining properties of water vapour diffusion on each specimen. As a final assessment was analysed the impact of properties of water vapour diffusion on the air tightness for each specimen. The general meaning of gaining higher air tightness with higher water vapour resistance was proved . It was shown that with raising thickness is usually gotten higher value of water vapour diffusion resistance. However it could not mean getting high air tightness. The crucial parameter is the quality of the material for gaining higher resistance against water vapour diffusion as well as for higher airtightness.
Design of heat exchanger chamber
Horník, Jan ; Naď, Martin (referee) ; Klučka, Ivan (advisor)
The master thesis is focused on the field of heat exchangers. Theoretical part makes the reader familiar with heat exchangers. Practical part is focused on design of chamber, which is part of heat exchanger. Practical part consists of strength calculation by standard ČSN EN 13445. Dimensions of tube sheet are gained in program Visual vessel design. Those parameters are used for creating of 3D model with accurate dimensions which is analyzed in ANSYS Workbench. Output of this analysis is evaluation by stress classification. Practical part is supplemented by drawing of heat exchanger.
Design of heat exchanger chamber
Horník, Jan ; Naď, Martin (referee) ; Klučka, Ivan (advisor)
The master thesis is focused on the field of heat exchangers. Theoretical part makes the reader familiar with heat exchangers. Practical part is focused on design of chamber, which is part of heat exchanger. Practical part consists of strength calculation by standard ČSN EN 13445. Dimensions of tube sheet are gained in program Visual vessel design. Those parameters are used for creating of 3D model with accurate dimensions which is analyzed in ANSYS Workbench. Output of this analysis is evaluation by stress classification. Practical part is supplemented by drawing of heat exchanger.
Air tightness of building structures and critical details
Vávra, Petr ; Tichomirov,, Vladimír (referee) ; Bečkovský, David (advisor)
In thesis is dealt with problematic of how the value of air permeability may be affected by properties for water vapour diffusion with regard to OSB material There were chosen two main brands of OSB at Czech trade market Two specimens of OSB with different thickness were chosen for each brand. As a first the specimens were tested for air tightness to work out a value of air permeability for each specimen. Afterwords, the testing was conducted for gaining properties of water vapour diffusion on each specimen. As a final assessment was analysed the impact of properties of water vapour diffusion on the air tightness for each specimen. The general meaning of gaining higher air tightness with higher water vapour resistance was proved . It was shown that with raising thickness is usually gotten higher value of water vapour diffusion resistance. However it could not mean getting high air tightness. The crucial parameter is the quality of the material for gaining higher resistance against water vapour diffusion as well as for higher airtightness.