National Repository of Grey Literature 2 records found  Search took 0.00 seconds. 
SERS spectroscopy of model biomolecules for SERS biosensing
Šubr, Martin ; Procházka, Marek (advisor) ; Michl, Martin (referee)
Title: SERS spectroscopy of model biomolecules for SERS biosensing Author: Martin Šubr Department: Institute of Physics of Charles University Supervisor: doc. RNDr. Marek Procházka, Dr., Institute of Physics of Charles University Abstract: The main requirement for surface enhanced Raman scattering (SERS)-based biomolecular sensing is high sensitivity and spectral reproducibility. For this purpose, ordered silver and gold nanostructures fabricated by magnetron sputtering and lithography methods at cooperating institutes were tested in this work. Reproducible SERS spectra of employed model biomolecules (amino acids, lysozyme and albumin) were obtained on ordered silver surfaces at concentrations 10-4 M - 10-6 M and as low as ≈ 10-7 M in the case of porphyrins. SERS spectra of certain biomolecules were also compared to spectra measured on silver colloid. The limit of detection provided by hydroxylamine-reduced silver colloid, using KCl as an aggregating agent, is substantially lower (on the order of 10-8 M for cysteine), but with lower spectral reproducibility. The main drawback of SERS spectra measured on silver surfaces was the occurrence of spurious bands resulting from the preparation procedure. In the case of sputter-deposited silver surfaces, it was found that keeping the substrates several hours in...
SERS spectroscopy of model biomolecules for SERS biosensing
Šubr, Martin ; Procházka, Marek (advisor) ; Michl, Martin (referee)
Title: SERS spectroscopy of model biomolecules for SERS biosensing Author: Martin Šubr Department: Institute of Physics of Charles University Supervisor: doc. RNDr. Marek Procházka, Dr., Institute of Physics of Charles University Abstract: The main requirement for surface enhanced Raman scattering (SERS)-based biomolecular sensing is high sensitivity and spectral reproducibility. For this purpose, ordered silver and gold nanostructures fabricated by magnetron sputtering and lithography methods at cooperating institutes were tested in this work. Reproducible SERS spectra of employed model biomolecules (amino acids, lysozyme and albumin) were obtained on ordered silver surfaces at concentrations 10-4 M - 10-6 M and as low as ≈ 10-7 M in the case of porphyrins. SERS spectra of certain biomolecules were also compared to spectra measured on silver colloid. The limit of detection provided by hydroxylamine-reduced silver colloid, using KCl as an aggregating agent, is substantially lower (on the order of 10-8 M for cysteine), but with lower spectral reproducibility. The main drawback of SERS spectra measured on silver surfaces was the occurrence of spurious bands resulting from the preparation procedure. In the case of sputter-deposited silver surfaces, it was found that keeping the substrates several hours in...

Interested in being notified about new results for this query?
Subscribe to the RSS feed.