National Repository of Grey Literature 7 records found  Search took 0.00 seconds. 
Differential Protection for Power Transformer
Bukvišová, Zuzana ; Wasserbauer, Vojtěch (referee) ; Orságová, Jaroslava (advisor)
This thesis explores power transformer protection and focuses on differential protection. It attempts to explain its principles and operating characteristic settings. The measurement was executed on devices SPAD 346 C and REF542plus, which can be used for differential protection. At the end, there is a comparison of results of operating characteristic measurement on both devices. Their function was tested at different cases, specifically when the differential current occurs in all phases or just one. The thesis includes a comparison of reaction times under fast increase of current. OMICRON CMC 256 plus was used as the test device. The data obtained by the measurement are processed in tables and charts.
Testing of Transformer Differential Protection
Judas, Jan ; Těžký, Jiří (referee) ; Orságová, Jaroslava (advisor)
My bachelor thesis deals with the protection of a transformer, the main focus of the thesis is the differential protection of a transformer, the principle of its function, stabilization and the operating characteristic. I suggested a way of measuring the operating characteristic of the protection SPAD 346 C (developed) by ABB company. As far as measurement is concerned, I used the testing device TZO3, which was, as well as the tested protection, configurated by a computer, into which the results of single measurements were put. The testing was performed via a kind of a test known as ,,TREND“ test for 3 various configurations of operating characteristic of protection and each measurement was scaled for 2 different ,,TREND“ testings. Two marginal operating characteristics were configurated and the third characteritic was configurated approximately between 2 marginal configurations . An error in the calculations of measurement was shown. Since there were two ,,TREND“ tests of steepness performed, there was a calculation of reaction time of protection conducted/performed as well.. All measured and calculated data were processed to graphs in order to illustrate differences among single measurements. I also provided explanations and calculations of possibilities of elimination of increase of electric current within reaction time of protection at steeper increase of ,,TREND“ test.
Steam Turbine for Compressor Drive
Beran, Petr ; Fiedler, Jan (referee) ; Kracík, Petr (advisor)
The goal of this diploma thesis is design of steam turbine for driving a compressor with mechanical power of 25 MW, while using a standard API 612. In the first chapter of this work there is calculation of the steam mass flow about value of 23.17 kg/s, the next chapter deals with the design of control stage with the diameter of 0.715 m, inner power of 1673.6 kW and thermodynamic efficiency of 68 %. The following chapter includes thermodynamic calculation of stage part about power of 26.37 MW at designed rotation speed 5722.5 rpm which corresponds to 105 % of rated speed and thermodynamic efficiency 84 %. For control stage and stage part there is a strength calculation control. The thesis also includes basic design of gland sealing system, the design of balance piston with diameter of 0.543 m and the choosing of axial and radial bearings due to acting forces. The conclusion chapter deals with operating characteristic of designed steam turbine. The thesis includes mechanical drawing of turbine.
Steam Turbine for Compressor Drive
Beran, Petr ; Fiedler, Jan (referee) ; Kracík, Petr (advisor)
The goal of this diploma thesis is design of steam turbine for driving a compressor with mechanical power of 25 MW, while using a standard API 612. In the first chapter of this work there is calculation of the steam mass flow about value of 23.17 kg/s, the next chapter deals with the design of control stage with the diameter of 0.715 m, inner power of 1673.6 kW and thermodynamic efficiency of 68 %. The following chapter includes thermodynamic calculation of stage part about power of 26.37 MW at designed rotation speed 5722.5 rpm which corresponds to 105 % of rated speed and thermodynamic efficiency 84 %. For control stage and stage part there is a strength calculation control. The thesis also includes basic design of gland sealing system, the design of balance piston with diameter of 0.543 m and the choosing of axial and radial bearings due to acting forces. The conclusion chapter deals with operating characteristic of designed steam turbine. The thesis includes mechanical drawing of turbine.
Differential Protection for Power Transformer
Bukvišová, Zuzana ; Wasserbauer, Vojtěch (referee) ; Orságová, Jaroslava (advisor)
This thesis explores power transformer protection and focuses on differential protection. It attempts to explain its principles and operating characteristic settings. The measurement was executed on devices SPAD 346 C and REF542plus, which can be used for differential protection. At the end, there is a comparison of results of operating characteristic measurement on both devices. Their function was tested at different cases, specifically when the differential current occurs in all phases or just one. The thesis includes a comparison of reaction times under fast increase of current. OMICRON CMC 256 plus was used as the test device. The data obtained by the measurement are processed in tables and charts.
Testing of Transformer Differential Protection
Judas, Jan ; Těžký, Jiří (referee) ; Orságová, Jaroslava (advisor)
My bachelor thesis deals with the protection of a transformer, the main focus of the thesis is the differential protection of a transformer, the principle of its function, stabilization and the operating characteristic. I suggested a way of measuring the operating characteristic of the protection SPAD 346 C (developed) by ABB company. As far as measurement is concerned, I used the testing device TZO3, which was, as well as the tested protection, configurated by a computer, into which the results of single measurements were put. The testing was performed via a kind of a test known as ,,TREND“ test for 3 various configurations of operating characteristic of protection and each measurement was scaled for 2 different ,,TREND“ testings. Two marginal operating characteristics were configurated and the third characteritic was configurated approximately between 2 marginal configurations . An error in the calculations of measurement was shown. Since there were two ,,TREND“ tests of steepness performed, there was a calculation of reaction time of protection conducted/performed as well.. All measured and calculated data were processed to graphs in order to illustrate differences among single measurements. I also provided explanations and calculations of possibilities of elimination of increase of electric current within reaction time of protection at steeper increase of ,,TREND“ test.
The Six Sigma methodology
Zajícová, Hana ; Jarošová, Eva (advisor) ; Malá, Ivana (referee)
Bachelor thesis deals with the desription of the statistical foundations and individual steps of Six Sigma, which are descibed by the DMAIC model. The thesis focuses on statistical process control and control charts. The main goal is to evaluate the possible use of control charts for attributes, namely the control chart for fraction nonconforming or p-diagram and to describe its properties expressed by the operating characteristic (OC). The influence of the sample size on the OC curve is examined. The last part of this theses deals with the desription of the xi-diagram as an alternative of the p-diagram. The properties of this alternative and classical p-diagram are compared.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.