National Repository of Grey Literature 6 records found  Search took 0.00 seconds. 
Study of the behavior of insulating materials in a high humidity environment
Havelka, Jindřich ; Peterková, Jitka (referee) ; Zach, Jiří (advisor)
Extruded polystyrene (XPS) is presented as non-absorbent material and it is applied in building construction with high moisture, such as inverted roof. The reason for that is a very good ratio of thermal and mechanical properties and it is used in moisture-loaded applications due to the closed pore structure and high diffusion resistance factor, which are declared by the manufacturers. Long-term experience and studies show that XPS accumulates moisture during long-term exposure in an environment with high humidity. A long-term water absorption test at full immersion for 84 days has been proposed to better illustrate the trend of increasing water absorption. A total of 6 products from different manufacturers that are recommended for inverted roof application, were tested. All tested XPS products have reached high amount of water absorption. The main goal was to map the real properties of XPS at high humidity loads. It was found that each product showed a different degradation of thermal conductivity at the same volume moisture value. Furthermore, there was found the connection between the surface structure and amount of water absorption. Products with waffle structure had higher humidity than products with a fine structure.
Airconditioning in a sanatorium
Batelka, Václav ; Andrys, Petr (referee) ; Rubina, Aleš (advisor)
Bachelor thesis describes the design of airconditioning for sanatorium in the village Liptal. The building is used for the rehabilitation of the treatment of Alzheimer´s deisease. The main task is to ensure the required exchange of fresh air and exhaust moisture loads from the interior. The swimming pool was further ensure coverage of heat loss in winter and heat gain in the summer. The device is designed to meet all hygienical, operational and functional requirements according to applicable legislation. In the theoretical part, the issues of water evaporation from the water surface. Calculation and design of the proposal addresses the specific design of airconditioning for equipment to operate the pool, electrotherapy and clubhouse. Result of this work is the design documentation for these aircondition equipment.
OPTIMIZATION OF WELLNESS AIR CONDITION
Kysilka, Michal ; Zubíček, Vojtěch (referee) ; Šikula, Ondřej (advisor)
The theme of diploma thesis is a design optimization of air distribution in swimming-pool hall with regard to free water surface evaporation. This problem was solved according to determined criterions with the aid of CFD simulation. Experimental measurement part of the thesis deals with evaporation problems where own formula for this physical phenomenon is determined. This formula is compared with already known algorithms. Author suggests that such formula might be integrated in CFD software.
Study of the behavior of insulating materials in a high humidity environment
Havelka, Jindřich ; Peterková, Jitka (referee) ; Zach, Jiří (advisor)
Extruded polystyrene (XPS) is presented as non-absorbent material and it is applied in building construction with high moisture, such as inverted roof. The reason for that is a very good ratio of thermal and mechanical properties and it is used in moisture-loaded applications due to the closed pore structure and high diffusion resistance factor, which are declared by the manufacturers. Long-term experience and studies show that XPS accumulates moisture during long-term exposure in an environment with high humidity. A long-term water absorption test at full immersion for 84 days has been proposed to better illustrate the trend of increasing water absorption. A total of 6 products from different manufacturers that are recommended for inverted roof application, were tested. All tested XPS products have reached high amount of water absorption. The main goal was to map the real properties of XPS at high humidity loads. It was found that each product showed a different degradation of thermal conductivity at the same volume moisture value. Furthermore, there was found the connection between the surface structure and amount of water absorption. Products with waffle structure had higher humidity than products with a fine structure.
OPTIMIZATION OF WELLNESS AIR CONDITION
Kysilka, Michal ; Zubíček, Vojtěch (referee) ; Šikula, Ondřej (advisor)
The theme of diploma thesis is a design optimization of air distribution in swimming-pool hall with regard to free water surface evaporation. This problem was solved according to determined criterions with the aid of CFD simulation. Experimental measurement part of the thesis deals with evaporation problems where own formula for this physical phenomenon is determined. This formula is compared with already known algorithms. Author suggests that such formula might be integrated in CFD software.
Airconditioning in a sanatorium
Batelka, Václav ; Andrys, Petr (referee) ; Rubina, Aleš (advisor)
Bachelor thesis describes the design of airconditioning for sanatorium in the village Liptal. The building is used for the rehabilitation of the treatment of Alzheimer´s deisease. The main task is to ensure the required exchange of fresh air and exhaust moisture loads from the interior. The swimming pool was further ensure coverage of heat loss in winter and heat gain in the summer. The device is designed to meet all hygienical, operational and functional requirements according to applicable legislation. In the theoretical part, the issues of water evaporation from the water surface. Calculation and design of the proposal addresses the specific design of airconditioning for equipment to operate the pool, electrotherapy and clubhouse. Result of this work is the design documentation for these aircondition equipment.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.