National Repository of Grey Literature 13 records found  previous11 - 13  jump to record: Search took 0.00 seconds. 
The influence of economic security unit of the volunteer firemen of the village on a budget selected municipalities in South County.
MICHAL, Petr
Civil Defence was in the Czechoslovak Socialist Republic in 1990, defined as a set of measures that are intended to prepare the state and the society it lives to defend before the war. Armed conflict in the then bipolar world could occur within a few days because of preparation for such a conflict took place on both sides for decades. Quitting called. Cold War, a period in which to minimize the possibility of a global military confrontation. However, the newly defined and continue to occur, often difficult to predict, security threats and risks. Protection of lives, health and property values, along with sovereignty, territorial integrity and protection of the democratic foundations of the newly formed Czech Republic, the basic duty of the state. Responsibility for the protection of the population in the newly constructed system of protection of the population in the Czech Republic, partially transferred and distributed to all levels of government, including municipalities and small towns. Newly constructed Integrated rescue system became progressively a linchpin in the coordination of activities and procedures in preparing for emergencies in rescue and clean up operations and to protect against the crisis states, and after the state of emergency. This thesis is aimed to carry out data collection from ten cities of the reporting period with extended powers, which is based in the South Region. File data collected will be evaluated and the evaluation in order to determine the economic performance of the financing protection of the population in a particular city. The assessment will be done in relation to the basic element of civil protection units which are voluntary municipal fire brigade. The thesis will be evaluated the impact of funding fire protection budget of the municipality. Work wonders, what is the trend in financing those units while trying to answer the question, what is the impact on the budget funding specific community. Both responses will be made a conclusion that communicate, whether financing is adequate fire protection units or not. Investigations will be carried out at one of the village extended powers, therefore, from a global perspective, this will not result in a valid conclusion about the crucial work. Wider research on the topic, with a similar focus, however, may, if the interests of society, such data can bring.
Condition of mobile water pumps of chosen fire protection units from the region of Liberec and possibilities of it's modernization
POLOPRUTSKÝ, Lukáš
Even today, there may be differences between the various facilities of fire protection in the field of portable pumps. Some units have a new and technically compliant mobile pumps, others have older portable pumps or even none. My primary interest was the current state of condition and technical level of the individual pumps. The Pumps and the issue of fire protection are mentioned in the first part. There is described a legal framework defining competencies, division, as well as the working of each fire protection units. Information on the various types of water pumps used not only in fire protection, working principles and specifics of mobile water pumps are also described here in a retrieval of information resources. The second part, which is my own research, is analysis of condition of mobile water pumps on selected sample of fire protection units from the region of Liberec. This practical task was realized by my myself questionnaires that I sent out to chosen fire protection units. Additional information was acquired thanks to personal interviews with representatives of the units. My field of interest was the quality of condition of mobile water pumps. The finally condition depends on the fact if the fire units own the pumps and their technical level. The monitored parameters were old pumps, maximum power, maximum discharge height, weight and maximum flow rate of the pump. The quality of the conditions of mobile water pumps of fire protection units was evaluated by using my own modification of operational analysis. The index of condition as a unique identifier was the outcome of the evaluation. The hypothesis The condition of mobile water pumps of chosen fire protection units corresponds today's technical possibilities - had prescientific character and it was formulated intuitively. The hypothesis also contained expectations of high and technically adequate condition of mobile water pumps of chosen fire protection units. Basis for the hypothesis flowed from the experience of recent years, when the fire brigade were gradually upgraded its founders. Based on the results it is possible to confirm the hypothesis and indicate the condition of chosen fire protection units from the region of Liberec as a sufficient because all of them pass the basic limit. To achieve four specific aims of this work the comparison of monitored technical parameters and the number of pumps with limit for condition was used. These aims of the thesis were complete thanks to these methods except one. It was the plan of modernization at the fire protection unit, which does not correspond amenities. Since the confirmation of the hypothesis, which states that mobile pumps amenities for today's technical possibilities, no need to drive to modernize the newer models. You are at least mentioned in the results of the work, and their technical parameters are included in the annex. If we take into account the practical point of view, this work is useful for the Fire Brigade Liberec region, such as document monitoring conditions of mobile water pumps of chosen fire protection unit from Liberec region.
Fire-fighting equipment for an efficient action of fire-fighting units in the neighbourhood Maj in Strakonice.
VINCÍK, Miroslav
The thesis analyses the current situation at the residential area Máj. It describes problems and defects preventing successful and early firefighting intervention, it tries to find a solution for an improvement of fire safety in buildings and suggests innovative precautions for complete revitalization of the residential area in terms of the fire protection. The aim of the work is to outline conditions of high quality that would allow the efficient intervention of fire protection units at the residential area Máj. When elaborating this work I considered the data obtained from the area planning documents, project documentation, legal regulations and technical directives concerning the fire safety area, the alarm plan of the region, my own investigation and the survey performed by using the questionnaire method in the residents of the residential area Máj in Strakonice. As a result of the findings I suggest in the thesis solutions, improving current conditions of firefighting intervention when implemented, and so enhancing the efficiency of the performance.

National Repository of Grey Literature : 13 records found   previous11 - 13  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.