Development of methodology and supporting tool for evaluation of measured values of high voltage poles grounding systems according standard PNE 33 3300-1
Kováč, Frederik ; Basík, Josef (referee) ; Toman, Petr (advisor)
Diploma thesis is oriented on measuring and evaluation of grounding conditions of HV pylons. In theoretical part is described theory of grounding including related legislation, impact of electric current on human body, methods of measuring earth resistance, soil resitivity and description of available measurers. Practical part is focused on measuring earth resistance of selected pylons and measuring procedures followed by evaluation of measurements according to person's safety from dangerous touch voltage and impact of lightings. For evauluation of measured data is created supporting tool in MS Excel. In the last part of thesis are described recommendations for cutting-down touch voltages.
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.
Development of methodology and supporting tool for evaluation of measured values of high voltage poles grounding systems according standard PNE 33 3300-1
Kováč, Frederik ; Basík, Josef (referee) ; Toman, Petr (advisor)
Diploma thesis is oriented on measuring and evaluation of grounding conditions of HV pylons. In theoretical part is described theory of grounding including related legislation, impact of electric current on human body, methods of measuring earth resistance, soil resitivity and description of available measurers. Practical part is focused on measuring earth resistance of selected pylons and measuring procedures followed by evaluation of measurements according to person's safety from dangerous touch voltage and impact of lightings. For evauluation of measured data is created supporting tool in MS Excel. In the last part of thesis are described recommendations for cutting-down touch voltages.
Evaluation of MV/LV network earthing systems
Sítař, Martin ; Topolánek, David (referee) ; Kopička, Marek (advisor)
This master's thesis deals with the measurement of grounding systems in HV/LV distribution networks, which includes grounding system of distribution substation and transmission lines. Explores the issue and principles for the measurement of parameters, which are important for the protection of persons and animals in order not to touch exposed conductive part accidentally, protection of electrical machines and equipment against high fault current and dangerous surges while the correct function of the connected electrical equipment is maintained. These parameters include earth potential rise, ground resistance, soil resistivity, touch voltage, step voltage and transferred potential to the LV network. The aim of this work is the preparation, analysis and subsequent evaluation for the real measurement in practice. These earthing-system measurements were carried out at the distribution station and the concrete pole with a section disconnector. Then a numerical model of the grounding system of concrete pole was created in ANSYS. Subsequent evaluation of the results as numerical terms (comparison measurements and simulated results) and evaluation in terms of analytical (measurement results compliance with the standard) including the numerical model of the earthing system is solved in the practical part of the master's thesis.