National Repository of Grey Literature 6 records found  Search took 0.00 seconds. 
Analysis of substances released from composite dental material
Fučík, Jan ; Řezáčová, Veronika (referee) ; Mravcová, Ludmila (advisor)
This master's thesis deals with a present problem of alternative dental fillings, which should replace amalgam fillings. Although there are health concerns about these alternative materials, especially resin composite fillings raise concerns, because they release potentionally harmful substances into the oral cavity. Accordingly even this medical device subjects various tests before releasing to the commercial market and one of these tests was carried out according to ČSN EN ISO 10993 and available scientific literature in the experimental part of this thesis. The amalgam controversy, substances used for manufacturing of resin dental fillings and analytical methods are described in the theoretical part of the thesis. In the experimental part of the thesis, 30 days long cumulative extraction experiments were carried out into various extraction mediums in order to assess suitability of new dental resin filling from ADM, a.s. by comparison with commercially available dental material from company GC EUROPE N.V. These samples were analysed by LC-MS and the amount of eluted substances from dental composites to extraction medium was quantified.
Ceramic nanofiber-reinforced composites
Bocian, Luboš ; Přikryl, Radek (referee) ; Poláček, Petr (advisor)
This thesis investigated how the addition of unsilanized and silanized ceramic SiO2 nanofibers into particle reinforced composite affects flexural strength, fracture toughness, total fracture work and temperature dependence of viscoelastic properties. Fracture surfaces were analyzed with SEM. Flexural strength always decreased with addition of nanofibers. Composites with silanized nanofibers showed higher flexural strength than those with unsilanized nanofibers. Fracture toughness was higher with addition of nanofibers. Fracture toughness of composites with silanized nanofibers was always lower than that of systems with unsilanized nanofibers. Total fracture work was lower with addition of nanofibers, but sharply increased in composites with 5 % of nanofibers. Glass transition temperature almost always increased with addition of nanofibers. Storage modulus increased with addition of nanofibers. Storage modulus was always lower in composites with silanized nanofibers.
Effect of Interlayer Composition on Bond Strength between FRC Framework and Composite Veneer
Ibarra, Jonatanh José ; Pavelka,, Vladimír (referee) ; Poláček, Petr (advisor)
Hlavním cílem této práce je studium aktuálního problému adheze mezi kompozitními materiály, a určení vlivu složení mezivrstvy v pevnosti adhezivního spoje mezi vláknové (FRC) a částicové (PFC) kompozity, používané ve stomatologii. FRC tyčinky byly vytvořené na bázi komerční dimetakrylatové pryskyřice a skleněných S vláken. PFC byl vytvořen ze směsi pryskyřic (bis-GMA a PEGDMA), plněných drceným barnatým sklem. Celkově bylo připraveno a vyzkoušeno 84 vzorků. Vzorky byly rozdělené do pěti hlavních skupin. První skupina byla vytvořena ze série vzorků bez mezivrstvy. Zbylé čtyři skupiny byly rozděleny dle složení mezivrstvy (tloušťky a druhu pryskyřic). Částicové kompozity vzorků se lišily obsahem plniva (0, 10, 40 hm %). FRC tyčinky byly stejné pro všechny vzorky. Univerzální testovací přístroj ZWICK Z010 byl použit k zjištění smykové pevnosti adhezivního spoje všech vzorků. Rastrovací elektronový mikroskop byl použít k pozorování místa porušení. Ze získaných výsledků vyplívá, že s přidáváním mezivrstvy mezi vláknovým a částicovým narůstá smyková pevnost spoje. Důležitost těchto výsledků je způsobená tím, že v posledních letech použití těchto materiálů ve stomatologii narůstá a adheze zůstává jeden z hlavních problémů při klinické praxi.
Analysis of substances released from composite dental material
Fučík, Jan ; Řezáčová, Veronika (referee) ; Mravcová, Ludmila (advisor)
This master's thesis deals with a present problem of alternative dental fillings, which should replace amalgam fillings. Although there are health concerns about these alternative materials, especially resin composite fillings raise concerns, because they release potentionally harmful substances into the oral cavity. Accordingly even this medical device subjects various tests before releasing to the commercial market and one of these tests was carried out according to ČSN EN ISO 10993 and available scientific literature in the experimental part of this thesis. The amalgam controversy, substances used for manufacturing of resin dental fillings and analytical methods are described in the theoretical part of the thesis. In the experimental part of the thesis, 30 days long cumulative extraction experiments were carried out into various extraction mediums in order to assess suitability of new dental resin filling from ADM, a.s. by comparison with commercially available dental material from company GC EUROPE N.V. These samples were analysed by LC-MS and the amount of eluted substances from dental composites to extraction medium was quantified.
Ceramic nanofiber-reinforced composites
Bocian, Luboš ; Přikryl, Radek (referee) ; Poláček, Petr (advisor)
This thesis investigated how the addition of unsilanized and silanized ceramic SiO2 nanofibers into particle reinforced composite affects flexural strength, fracture toughness, total fracture work and temperature dependence of viscoelastic properties. Fracture surfaces were analyzed with SEM. Flexural strength always decreased with addition of nanofibers. Composites with silanized nanofibers showed higher flexural strength than those with unsilanized nanofibers. Fracture toughness was higher with addition of nanofibers. Fracture toughness of composites with silanized nanofibers was always lower than that of systems with unsilanized nanofibers. Total fracture work was lower with addition of nanofibers, but sharply increased in composites with 5 % of nanofibers. Glass transition temperature almost always increased with addition of nanofibers. Storage modulus increased with addition of nanofibers. Storage modulus was always lower in composites with silanized nanofibers.
Effect of Interlayer Composition on Bond Strength between FRC Framework and Composite Veneer
Ibarra, Jonatanh José ; Pavelka,, Vladimír (referee) ; Poláček, Petr (advisor)
Hlavním cílem této práce je studium aktuálního problému adheze mezi kompozitními materiály, a určení vlivu složení mezivrstvy v pevnosti adhezivního spoje mezi vláknové (FRC) a částicové (PFC) kompozity, používané ve stomatologii. FRC tyčinky byly vytvořené na bázi komerční dimetakrylatové pryskyřice a skleněných S vláken. PFC byl vytvořen ze směsi pryskyřic (bis-GMA a PEGDMA), plněných drceným barnatým sklem. Celkově bylo připraveno a vyzkoušeno 84 vzorků. Vzorky byly rozdělené do pěti hlavních skupin. První skupina byla vytvořena ze série vzorků bez mezivrstvy. Zbylé čtyři skupiny byly rozděleny dle složení mezivrstvy (tloušťky a druhu pryskyřic). Částicové kompozity vzorků se lišily obsahem plniva (0, 10, 40 hm %). FRC tyčinky byly stejné pro všechny vzorky. Univerzální testovací přístroj ZWICK Z010 byl použit k zjištění smykové pevnosti adhezivního spoje všech vzorků. Rastrovací elektronový mikroskop byl použít k pozorování místa porušení. Ze získaných výsledků vyplívá, že s přidáváním mezivrstvy mezi vláknovým a částicovým narůstá smyková pevnost spoje. Důležitost těchto výsledků je způsobená tím, že v posledních letech použití těchto materiálů ve stomatologii narůstá a adheze zůstává jeden z hlavních problémů při klinické praxi.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.