National Repository of Grey Literature 4 records found  Search took 0.00 seconds. 
Analysis of effect of solar radiation concentration on the thermal insulation degradation in the flat roof construction
Židek, Ondřej ; Běžel, Jakub (referee) ; Žák, Antonín (advisor)
The master´s thesis analyzes influence of direct and reflected solar radiation to heat strain and degradation of thermal insulation in the flat roof construction. In many building was a problem in a significant degradation of thermal insulation made from expanded polystyrene in the vicinity of glass surfaces. To determine the causes of this problem, it was necessary to study and test the properties of building materials and the physical nature of the effect of solar radiation on the building structure. In the introductory section lists the cases of buildings with degradation of thermal insulation and existing knowledge on this issue. The theoretical part describes the technical properties of thermal insulating materials used in the flat roof construction, nature and division of solar radiation, optical laws of light reflection and physical theory to explain the technical thermal behavior of building materials and structures. The last part describes a practical model and analyzing measured data in thermal stress in the flat roof construction. The practical part also determines the importance of different influences configuration structures using to dynamic simulations. At the end of the practical part they are validated theoretical knowledge obtained by analyzing data from a practical model.
Study of the behavior of insulating materials in a high humidity environment
Havelka, Jindřich ; Peterková, Jitka (referee) ; Zach, Jiří (advisor)
Extruded polystyrene (XPS) is presented as non-absorbent material and it is applied in building construction with high moisture, such as inverted roof. The reason for that is a very good ratio of thermal and mechanical properties and it is used in moisture-loaded applications due to the closed pore structure and high diffusion resistance factor, which are declared by the manufacturers. Long-term experience and studies show that XPS accumulates moisture during long-term exposure in an environment with high humidity. A long-term water absorption test at full immersion for 84 days has been proposed to better illustrate the trend of increasing water absorption. A total of 6 products from different manufacturers that are recommended for inverted roof application, were tested. All tested XPS products have reached high amount of water absorption. The main goal was to map the real properties of XPS at high humidity loads. It was found that each product showed a different degradation of thermal conductivity at the same volume moisture value. Furthermore, there was found the connection between the surface structure and amount of water absorption. Products with waffle structure had higher humidity than products with a fine structure.
Study of the behavior of insulating materials in a high humidity environment
Havelka, Jindřich ; Peterková, Jitka (referee) ; Zach, Jiří (advisor)
Extruded polystyrene (XPS) is presented as non-absorbent material and it is applied in building construction with high moisture, such as inverted roof. The reason for that is a very good ratio of thermal and mechanical properties and it is used in moisture-loaded applications due to the closed pore structure and high diffusion resistance factor, which are declared by the manufacturers. Long-term experience and studies show that XPS accumulates moisture during long-term exposure in an environment with high humidity. A long-term water absorption test at full immersion for 84 days has been proposed to better illustrate the trend of increasing water absorption. A total of 6 products from different manufacturers that are recommended for inverted roof application, were tested. All tested XPS products have reached high amount of water absorption. The main goal was to map the real properties of XPS at high humidity loads. It was found that each product showed a different degradation of thermal conductivity at the same volume moisture value. Furthermore, there was found the connection between the surface structure and amount of water absorption. Products with waffle structure had higher humidity than products with a fine structure.
Analysis of effect of solar radiation concentration on the thermal insulation degradation in the flat roof construction
Židek, Ondřej ; Běžel, Jakub (referee) ; Žák, Antonín (advisor)
The master´s thesis analyzes influence of direct and reflected solar radiation to heat strain and degradation of thermal insulation in the flat roof construction. In many building was a problem in a significant degradation of thermal insulation made from expanded polystyrene in the vicinity of glass surfaces. To determine the causes of this problem, it was necessary to study and test the properties of building materials and the physical nature of the effect of solar radiation on the building structure. In the introductory section lists the cases of buildings with degradation of thermal insulation and existing knowledge on this issue. The theoretical part describes the technical properties of thermal insulating materials used in the flat roof construction, nature and division of solar radiation, optical laws of light reflection and physical theory to explain the technical thermal behavior of building materials and structures. The last part describes a practical model and analyzing measured data in thermal stress in the flat roof construction. The practical part also determines the importance of different influences configuration structures using to dynamic simulations. At the end of the practical part they are validated theoretical knowledge obtained by analyzing data from a practical model.