National Repository of Grey Literature 3 records found  Search took 0.01 seconds. 
Optical path difference active control mechanism
Neumanová, Anna ; Šulc, Václav (referee) ; Špaček, Matěj (advisor)
There is a long-term development of the Coherence-Controlled Holographic Microscope (CCHM) ongoing in the Laboratory of Experimental Biophotonics at the Faculty of Mechanical Engineering in Brno. A mechanism for active control of the optical path length needs to be implemented in the imaging setup of the microscope. The reason is the high sensitivity of the microscope to the optical path difference of~its~optical branches. Therefore, the mechanism must meet the high-resolution requirements. First, suitable mechanisms for this application are compared. Based on the research, three conceptual designs are presented. For the selected design, a complete technical solution is elaborated. The mechanism is then fabricated, assembled and tested in terms of its motion characteristics.
Voltage Conveyors in Linear Blocks
Dohnal, Pavel ; Jeřábek, Jan (referee) ; Koton, Jaroslav (advisor)
The main goal of this diploma thesis will be realization of tunable frequency filters using voltage conveyors, that are only little explored yet. At the beginnig of diploma thesis the frequency filters and their types will be defined. The theory of voltage conveyors based on principle of duality results from the character of current conveyors. Accordingly these active components will be closely presented. At first there will be defined individual types of voltage conveyors and their closer characteristics. Then design methods of frequency filters using unconventional active components will be described. There will be defined the method of the total admitance net, subsequently design using synthetic components and at the end there will be presented method using follow graphs that will be used to design concrete circuit solution. Using follow graphs method will be found circuit solutions of current structures with unconventional active components. During searching circuit solutions will be very important the posibility to operate the quality factor. That can be obtained by two ways. One way is the activ operation which is done by coeficients of the activ component. Other way is operating using the passiv component. There are found 26 circuits that realize condition of active operating using two active and four passive components. One of these circuits will be chosen and simulated in simulation program PSpice. To compare both methods of operation there will be compiled some circuit with passive operating with two active and five passive components and one of the passive components will be able to operate the quality factor. This circuit will be simulated in the simulation program PSpice again. The circuit will be real compiled and experimentaly measured in laboratory. Results of this measurement will be compared with calculated values and with values acquired from the simulations.
Voltage Conveyors in Linear Blocks
Dohnal, Pavel ; Jeřábek, Jan (referee) ; Koton, Jaroslav (advisor)
The main goal of this diploma thesis will be realization of tunable frequency filters using voltage conveyors, that are only little explored yet. At the beginnig of diploma thesis the frequency filters and their types will be defined. The theory of voltage conveyors based on principle of duality results from the character of current conveyors. Accordingly these active components will be closely presented. At first there will be defined individual types of voltage conveyors and their closer characteristics. Then design methods of frequency filters using unconventional active components will be described. There will be defined the method of the total admitance net, subsequently design using synthetic components and at the end there will be presented method using follow graphs that will be used to design concrete circuit solution. Using follow graphs method will be found circuit solutions of current structures with unconventional active components. During searching circuit solutions will be very important the posibility to operate the quality factor. That can be obtained by two ways. One way is the activ operation which is done by coeficients of the activ component. Other way is operating using the passiv component. There are found 26 circuits that realize condition of active operating using two active and four passive components. One of these circuits will be chosen and simulated in simulation program PSpice. To compare both methods of operation there will be compiled some circuit with passive operating with two active and five passive components and one of the passive components will be able to operate the quality factor. This circuit will be simulated in the simulation program PSpice again. The circuit will be real compiled and experimentaly measured in laboratory. Results of this measurement will be compared with calculated values and with values acquired from the simulations.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.