Choice of polymer samples geometry for measurement of elongational viscosity using ser universal testing platform
Filip, Petr ; Švrčinová, Petra
Generation of purely uniaxial elongational flow of polymer melts is very uneasy problem. It seems that each hitherto developed device for measurement of uniaxial elongational viscosity also produces - to some extent - a planar flow. During the last period there has been questioned - based on this reasoning - the applicability of a SER Universal Testing Platform and was recommended the range of rectangular dimensions of polymer samples for which measurements of uniaxial elongational viscosity is possible to take into account. The aim of this contribution consists in verification of invariantness of uniaxial elongational measurements using the SER Universal Testing Platform with respect to the dimensions of polymer samples applied. There is shown that for sufficiently broad region of admissible widths and thicknesses the results are identical. For these measurements there was used LDPE Escorene (Exxon, U.S.A.).
A note to the measurement of extensional viscosity using SER Universal Testing Platform with different shapes of polymer samples
Švrčinová, Petra ; Filip, Petr ; Kharlamov, Alexander
For polymer melts, with respect to their numerical simulations, there were recommended to apply polymer samples (rectangles) with a width not exceeding 8 mm and a thickness less than 0.4 mm. The aim of this contribution is to document - for material used (LDPE Escorene, Exxon, USA) - the invariantness of the elongational viscosity measured with respect to sample dimensions including its width and thickness. The width of the samples used consecutively attained 12.7, 11.0, 9.3, and 7.4 mm; the thickness also ranged across a sufficiently broad interval (0.3-1.1mm). Temperature was set to 180, 190, and 200oC. For the measurements there were used the SER Universal Testing Platform from the Xpansion Instruments; the model SER-HV-P01 was applied with a Physica MCR501 rotational rheometer host system. The results obtained justify usage of a 'classical' width 12.7 mm (1/2") more suitable for better manipulation with a sample, especially its fixing to both drums perpendicularly to the clamps.
Měření elongační viskozity PE materiálů
Švrčinová, Petra ; Kharlamov, Alexander ; Filip, Petr
This contribution aims at the measurements of elongation viscosity for polyethylene materials. The approach is analysed from the viewpoint of possible degradation of materials tested and the emphasis is paid to admissible acceleration of the whole measuring process. There is presented a hint how to simplify (and accelerate) the measurements for a suitable class of materials.