Pulse charging of lead-acid accumulator using negative current steps
Kantor, Pavel ; Vaněk, Jiří (referee) ; Křivík, Petr (advisor)
The lead-acid batteries are the most commonly used electrochemical power sources and are the oldest type of secondary battery cells. This master thesis provides a short introduction to the lead-acid batteries. It shows possible ways of sorting from different points of view, describes construction of lead-acid batteries, parameters of lead-acid batteries and electrochemical and physical reactions inside the battery. Futher the thesis deals with pulse charging of lead-acid batteries. The thesis describes the production of a set of experimental electrodes for electrochemical workplace resources. The thesis introduces the develepment environment Agilent VEE PRO and demonstrates its capabilities. The final part of this thesis are experiments focusing on the pulse charging using negative current pulses and evaluate the effect of different pulse modes on cells.
Antistatistic properties of materials in engineering practice
Vodička, Tomáš ; Rozsívalová, Zdenka (referee) ; Frk, Martin (advisor)
The bachelor thesis deals with the properties of antistatic materials in engineering practice. The theoretical part described mathematically and physically electric field, the principle of electrification, triboelectric effect, types of electrostatic discharges, types of antitatic materials and methods of measurement surface and volume resistivity. In the practical part is designed the automated measuring workplace with electrometer Keithley 6517 and with the test chamber Keithley 8009, creating an application in Agilent VEE Pro, measurement of surface and volume resistivity on commercial materials and materials with various surface finishes, realized by cathode sputtering and the inclusion of materials in each group.
Designing an automated workplace for charge and high-impedance measurement
Nemček, Jakub ; Bartušek, Karel (referee) ; Gescheidtová, Eva (advisor)
This barchelor thesis is about Desig an automated workplace forchargeable and high-impedant measurements. This automated workplace is realized by tubular aspiration capacitor, which is connected via differential converter U/I to data acquisition switch unit HP 34970A. The data acquisition switch unit HP 34970A is also connected by serial line RS-232 to Computer (PC), on which the directed program Agilent VEE Pro 7.0 is installed. To the right connection data acquisition switch unit HP 34970A and PC is necessary to set the same parameters on data acquisition switch unit HP 34970A, such in I/O config and also in Instrument manager too. In Instrument manager is requisite to set Plug und Play driver for data acquisition switch unit HP 34970A. The programing in Agilent VEE Pro 7.0 is based on object oriented programming. To start the program press the button “START“ and automatic measuring of concentration air ionts, will start the process (the trend is marked to the graph). The program is indicated if the ventilator blows an air in the aspiration capacitor and draws the trend of voltage on this ventilator to the graph. To stop the program press the buton “STOP“. Measured data are exported to program Excel. For the export Excel has to be running before the process. The function is verifing by measuring of background negativ a positiv ionts, by influence of position the source of ionts behind the aspiration capacitor and by influence of materials (metal plate, paper carton, wood, conductive paint) to the concentration of negativ ionts.
Pulse charging of lead-acid accumulator using negative current steps
Kantor, Pavel ; Vaněk, Jiří (referee) ; Křivík, Petr (advisor)
The lead-acid batteries are the most commonly used electrochemical power sources and are the oldest type of secondary battery cells. This master thesis provides a short introduction to the lead-acid batteries. It shows possible ways of sorting from different points of view, describes construction of lead-acid batteries, parameters of lead-acid batteries and electrochemical and physical reactions inside the battery. Futher the thesis deals with pulse charging of lead-acid batteries. The thesis describes the production of a set of experimental electrodes for electrochemical workplace resources. The thesis introduces the develepment environment Agilent VEE PRO and demonstrates its capabilities. The final part of this thesis are experiments focusing on the pulse charging using negative current pulses and evaluate the effect of different pulse modes on cells.
Antistatistic properties of materials in engineering practice
Vodička, Tomáš ; Rozsívalová, Zdenka (referee) ; Frk, Martin (advisor)
The bachelor thesis deals with the properties of antistatic materials in engineering practice. The theoretical part described mathematically and physically electric field, the principle of electrification, triboelectric effect, types of electrostatic discharges, types of antitatic materials and methods of measurement surface and volume resistivity. In the practical part is designed the automated measuring workplace with electrometer Keithley 6517 and with the test chamber Keithley 8009, creating an application in Agilent VEE Pro, measurement of surface and volume resistivity on commercial materials and materials with various surface finishes, realized by cathode sputtering and the inclusion of materials in each group.
Designing an automated workplace for charge and high-impedance measurement
Nemček, Jakub ; Bartušek, Karel (referee) ; Gescheidtová, Eva (advisor)
This barchelor thesis is about Desig an automated workplace forchargeable and high-impedant measurements. This automated workplace is realized by tubular aspiration capacitor, which is connected via differential converter U/I to data acquisition switch unit HP 34970A. The data acquisition switch unit HP 34970A is also connected by serial line RS-232 to Computer (PC), on which the directed program Agilent VEE Pro 7.0 is installed. To the right connection data acquisition switch unit HP 34970A and PC is necessary to set the same parameters on data acquisition switch unit HP 34970A, such in I/O config and also in Instrument manager too. In Instrument manager is requisite to set Plug und Play driver for data acquisition switch unit HP 34970A. The programing in Agilent VEE Pro 7.0 is based on object oriented programming. To start the program press the button “START“ and automatic measuring of concentration air ionts, will start the process (the trend is marked to the graph). The program is indicated if the ventilator blows an air in the aspiration capacitor and draws the trend of voltage on this ventilator to the graph. To stop the program press the buton “STOP“. Measured data are exported to program Excel. For the export Excel has to be running before the process. The function is verifing by measuring of background negativ a positiv ionts, by influence of position the source of ionts behind the aspiration capacitor and by influence of materials (metal plate, paper carton, wood, conductive paint) to the concentration of negativ ionts.