National Repository of Grey Literature 3 records found  Search took 0.01 seconds. 
The Reliability of Measuring on the Skytec Interactive Ski Simulator
Novotný, Otomar ; Jindra, Matouš (advisor) ; Fořterová, Petra (referee)
Title: The Reliability of Measuring on the Skytech Interactive Ski Simulator Objectiv: The goal of this work is to investigate the reliability of the measurement of energy expenditure on the Skytech Interactive Ski Simulator. Methods: The sample consisted of 14 subjects, among which were 9 boys and 5 girls. The value of energy expenditure was measured by indirect calorimetry using the energy equivalent and respiratory exchange ratio. For the measurement of respiratory gases, the Metamax 3B metabolic analyzer and for the analysis of heart rate, the Polar S610 heart rate monitor were used. The subjects completed two measurements, each lasting 6 minutes. During this time, the data needed for subsequent calculations reliability were measured. Assuming that the pair of measuring has a two-dimensional distribution, the reliability equals the correlation coefficient. It was computed using the maximum likelihood method. Results: The measurement of energy expenditure on the Skytec Interactive Simulator provided consistent and reliable results. The findings in this study can be applied to further testing on this machine. Conclusion: The reliability of energy expenditure reached 0,84, a result better than the usual values of reliability tests, which may typically be about 0,8. Keywords: Energy expenditure,...
The Reliability of Measuring on the Skytec Interactive Ski Simulator
Novotný, Otomar ; Jindra, Matouš (advisor) ; Fořterová, Petra (referee)
Title: The Reliability of Measuring on the Skytech Interactive Ski Simulator Objectiv: The goal of this work is to investigate the reliability of the measurement of energy expenditure on the Skytech Interactive Ski Simulator. Methods: The sample consisted of 14 subjects, among which were 9 boys and 5 girls. The value of energy expenditure was measured by indirect calorimetry using the energy equivalent and respiratory exchange ratio. For the measurement of respiratory gases, the Metamax 3B metabolic analyzer and for the analysis of heart rate, the Polar S610 heart rate monitor were used. The subjects completed two measurements, each lasting 6 minutes. During this time, the data needed for subsequent calculations reliability were measured. Assuming that the pair of measuring has a two-dimensional distribution, the reliability equals the correlation coefficient. It was computed using the maximum likelihood method. Results: The measurement of energy expenditure on the Skytec Interactive Simulator provided consistent and reliable results. The findings in this study can be applied to further testing on this machine. Conclusion: The reliability of energy expenditure reached 0,84, a result better than the usual values of reliability tests, which may typically be about 0,8. Keywords: Energy expenditure,...
The Reliability of Measuring on the Skytech Interactive Ski Simulator
Novotný, Otomar ; Jindra, Matouš (advisor) ; Matošková, Petra (referee)
Title: The Reliability of Measuring on the Skytech Interactive Ski Simulator Objectiv: The goal of this work is to investigate the reliability of the measurement of energy expenditure on the Skytech Interactive Ski Simulator. Methods: The sample consisted of 14 subjects, among which were 9 boys and 5 girls. The value of energy expenditure was measured by indirect calorimetry using the energy equivalent and respiratory exchange ratio. For the measurement of respiratory gases, the Metamax 3B metabolic analyzer and for the analysis of heart rate, the Polar S610 heart rate monitor were used. The subjects completed two measurements, each lasting 6 minutes. During this time, the data needed for subsequent calculations reliability were measured. Assuming that the pair of measuring has a two-dimensional distribution, the reliability equals the correlation coefficient. It was computed using the maximum likelihood method. Results: The measurement of energy expenditure on the Skytec Interactive Simulator provided consistent and reliable results. The findings in this study can be applied to further testing on this machine. Conclusion: The reliability of energy expenditure reached 84%, a result better than the usual values of reliability tests, which may typically be about 80%. Keywords: Energy expenditure,...

See also: similar author names
56 NOVOTNÝ, Ondřej
5 Novotný, Oldřich
56 Novotný, Ondřej
2 Novotný, Ota
Interested in being notified about new results for this query?
Subscribe to the RSS feed.