National Repository of Grey Literature 2 records found  Search took 0.00 seconds. 
Analysis of AVG signals
Musil, Václav ; Sekora, Jiří (referee) ; Rozman, Jiří (advisor)
The presented thesis discusses the basic analysis methods of arteriovelocitograms. The core of this work rests in classification of signals and contribution to possibilities of noninvasive diagnostic methods for evaluation patients with peripheral ischemic occlusive arterial disease. The classification employs multivariate statistical methods and principles of neural networks. The data processing works with an angiographic verified set of arteriovelocitogram dates. The digital subtraction angiography classified them into 3 separable classes in dependence on degree of vascular stenosis. Classification AVG signals are represented in the program by the 6 parameters that are measured on 3 different places on each patient’s leg. Evaluation of disease appeared to be a comprehensive approach at signals acquired from whole patient’s leg. The sensitivity of clustering method compared with angiography is between 82.75 % and 90.90 %, specificity between 80.66 % and 88.88 %. Using neural networks sensitivity is in range of 79.06 % and 96.87 %, specificity is in range of 73.07 % and 91.30 %.
Analysis of AVG signals
Musil, Václav ; Sekora, Jiří (referee) ; Rozman, Jiří (advisor)
The presented thesis discusses the basic analysis methods of arteriovelocitograms. The core of this work rests in classification of signals and contribution to possibilities of noninvasive diagnostic methods for evaluation patients with peripheral ischemic occlusive arterial disease. The classification employs multivariate statistical methods and principles of neural networks. The data processing works with an angiographic verified set of arteriovelocitogram dates. The digital subtraction angiography classified them into 3 separable classes in dependence on degree of vascular stenosis. Classification AVG signals are represented in the program by the 6 parameters that are measured on 3 different places on each patient’s leg. Evaluation of disease appeared to be a comprehensive approach at signals acquired from whole patient’s leg. The sensitivity of clustering method compared with angiography is between 82.75 % and 90.90 %, specificity between 80.66 % and 88.88 %. Using neural networks sensitivity is in range of 79.06 % and 96.87 %, specificity is in range of 73.07 % and 91.30 %.

See also: similar author names
1 Musil, Viktor
1 Musil, Vilém
11 Musil, Vladimír
4 Musil, Vojtěch
6 Musil, Vít
Interested in being notified about new results for this query?
Subscribe to the RSS feed.