National Repository of Grey Literature 63 records found  beginprevious52 - 61next  jump to record: Search took 0.00 seconds. 
Optimalization and application of iodine spectrophotometric determination in soils.
HŘIVNÁČ, Jakub
This work deals with the content of iodine in soils, furthermore with obtaining and processing samples from four selected sampling areas, all of which are in the proximity of the Arnoštov settlement in district Prachatice in the foothills of Šumava. The soil samples were obtained from forest, meadow, pasture and fallow soil in 2009 to 2011. The iodine content in the soils was determined by using the spectrophotometric method, which had been optimized for the soil samples. Iodine concentration in lysimeter water was determined by using method inductively coupled plasma - mass spectrometry. The results obtained from each sampling areas were compared with each other and with the results from other areas. Consequently, the iodine concentration results in the soils were compared with the iodine concentration in lysimeter waters. It was found, that the highest iodine content in soils was measured in a sample obtained from Area 1 (meadow), part B in a depth of 16 - 30 cm in June of 2009, namely a content of 8,67 mg of I per kg of dry soil. The lowest content of 1,42 mg of I per kg of soil was found in the area 4 (forest), sample obtained in June of 2010, in the L horizon. By comparing iodine content with iodine concentrations in lysimeter waters, it was concluded that the concentration of iodine in lysimeter waters does not depend on iodine concentrations in soils and that it does not even represent the absolute iodine content in soil, as was determined by comparing the results from Arnoštov with data acquired from Agrovýzkum Rapotín in Jeseníky.
Blood values of sheep at a defined intake of selenium and iodine
KOCÁBOVÁ, Ivana
The theoretical part is concerned with the functional application of selenium and iodine supplementation methods, risks disproportionate to their income, including changes in biochemical and hematological parameters and evaluation methods of adequate saturation. The practical part analyzes the results of experiments on sheep with a defined content of selenium and iodine in the ration evaluation of selected indicators of the metabolic profile of ewes and their lambs. The results are processed statistically. It reflected the dynamics and interactions of monitored parameters.
Independent monitoring of Nuclear power plant Temelin environs by Regional centrum of SONS České Budějovice. Project of independent monitoring NPPTE in the case of Emergency incident.
ZEMAN, Karel
The State Office for Nuclear Safety (SONS) and the National Radiation Protection Institute (NRPI) are involved in independent monitoring of surrounding areas of nuclear power plants (NPPs), in accordance with the Czech legislative requirements (Decree No. 319/2002 Coll. on radiation monitoring network (RMS), as amended by Decree No. 27/2006 Coll.). The monitoring includes surveillance of environmental samples, in which radionuclides can be detected in case of emergency event, i.e. radioactivity release from the NPP. Another part of the monitoring is measurement of photon dose equivalent, continuously in the air (early detection network - SVZ) or using thermoluminescent dosimeters (TLD) placed in SONS monitoring points in the NPP vicinity. Environmental sampling and evaluation of photon dose equivalent in the air is carried out in regular intervals. The 137Cs and 131I activity is measured by gamaspectrometry method used with Gamat evaluation program, according to SONS internal procedure (VDMI). Tritium activity in surface water is measured by liquid scintillation spectrometer Beta TriCarb made by Canberra Packard Company, according to methodology CSN ISO 9698 (757635). Evaluation of dose equivalent rate is carried out continuously by LB 6360 proportional probe and LB 6500-3 Geiger-Muller tube located in RC Building in Ceske Budejovice. TLD evaluation is carried out by NRPI laboratory in Prague and the results are sent to SONS RC Ceske Budejovice. Goal of this work is to provide a set of results of the independent monitoring in surrounding areas of Temelin NPP (ETE) carried out between 1999 and 2009, by determination of volume, mass or surface activity of environmental samples (137Cs and 131I) and spot samples of water (3H) taken from SONS monitoring points near ETE . The set of such results should provide a baseline reference values for normal (pre-accident) situations. Additionally, based on the long term of the ETE surrounding surveillance, it can be shown that the ETE operation represents no threat to the health of the critical population group, and that the radiation situation in the ETE surrounding is stable. It can be also shown that the ETE operator meets requirements and conditions of authorized limits for discharging radionuclides into the environment. Procedures and method of independent environmental monitoring in the ETE surrounding during emergency events can be proposed on the basis of many years of experience with proven methodologies, experience with sampling locations, staffing and organization of measurement.
Optimization of the amount of iodine contrast agent (ICU) in CT scan examinations on a multislice CT scanner (64-detector row)
KRAJÍČEK, Ondřej
In my work, I focused on the optimization of the amount of iodine contrast agent during CT scan examinations by comparing various amounts of the contrast agent per kilogram of a patient{\crq}s body weight. I compared three groups of weight amounts: 1 mL/kg vs. 1.25 mL/kg vs. 1.5 mL/kg. I measured the differences in the enhancement of organs and blood vessels of the abdominal cavity. Their enhancement levels were compared quantitatively in the areas of interest by determining Hounsfield units in the aorta and parenchyma of the abdominal organs, and qualitatively by using an independent evaluation by a radiologist. Measurements were made on the GE Lightspeed 64-detector row CT scanner with pressure injector. No parameters were changed during the entire study, enabling the maintenance of standard conditions for high-quality comparisons in all examinations. Patients with any significant lesion in the organ to be measured were excluded from the study measurements, and patients at risk of circulation disorder (patients with severe conditions, such as heart failure, shock, and others) were also not enrolled. A contrast agent with a constant amount of iodine amounting to 300 mg/mL was used for the measurements. The study population comprised 120 patients, of which 51 were women and 69 men. The following data were recorded for each measurement: examination number, age, sex, body weight, HU values, and radiologist{\crq}s evaluation. The data were recorded in tables and further analyzed. Various HU enhancement levels were compared and evaluated and subsequently correlated with the radiologist{\crq}s evaluation. Optimal values of the amount of contrast agent were also compared with those routinely used at the facility concerned. This work provided optimal values of the amount of contrast agent for the examination of abdominal organs and adjusted standards for a CT scan facility. I believe my bachelor{\crq}s thesis contributed to a more precise dosing of the contrast agent during CT scan examinations.
Influence of the contrast medium iodine concentration on quality of the CT examination
RANŠOVÁ, Pavlína
Our work focused on determining absolute and relative density of various contrast agents in relation to iodine contents using in vitro and in vivo methods. It was documented that the relative density of contrast agents increases with the decreasing contents of iodine, i.e. density absolute values vary inversely as iodine content in these substances. Four various agents, bearing commercial names Visipaque 270, Visipaque 320, Ultravist 370 and Iomeron 400, in their original glass packing were used for our in vitro measurements. The measurements were carried out using CT equipment Emotion Duo (Siemens, Forchheim, Germany). Individual packing of the contrast agents were scanned by means of a standard protocol and under standard conditions. The obtained data were entered into tables. A retrospectively selected array of patients with standard scan of their stomachs was used for our in vivo measurements with a defined standard protocol using the same CT equipment and pressure injector CT 9000 Advantage (Liebel-Flarsheim, Mallinckrodt, the U.S.A.). The following data from 258 patients were recorded: age, sex, blood density after administering contrast agent in vitro on the level of diaphragm hiatus and on the bifurcation level, AP dimension of the patients on the hiatus level. Mean densities of the individual kinds of contrast agents were compared and a good correlation with the in vitro measurements was found out. The measured values were then analysed. The interdependence was studied in the measured densities and age, density changes measured on the hiatus level and on the bifurcation level for the individual contrast agents. The interdependence of the blood density on the AP dimension of the patients was also studied due to its practical use and it was documented that there is a good correlation of the decreasing density with the AP dimension as a simple parameter used instead of finding out patients{\crq} weights.

National Repository of Grey Literature : 63 records found   beginprevious52 - 61next  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.