National Repository of Grey Literature 12 records found  previous11 - 12  jump to record: Search took 0.00 seconds. 
Adiabatic air cooling
Silbernágl, Petr ; Blasinski, Petr (referee) ; Rubinová, Olga (advisor)
The diploma thesis deals deals with the designing and assessment of the two variants of cooling and humidifying the air in the production hall for cotton in Humpolec. The system is proposed to fulfil hygienic, operational, economic and functional requirements for indoor microclimate of the production hall. The task of this system is the transport of cooler air to interior and the covering of heat gains all year round. The equipment is also designed for the regulation of air humidity in the interior. The theoretical part is devoted to air humidification and air humidification device. Calculation of the project and then a specific proposal, two variants for air distribution level studies. Both variants are treated as project documentation. Experimental part is devoted to the measurement on the measuring path containing adiabatic humidifier in the laboratory. The benefit of the experiment is to verify the data from the manufacturer adiabatic humidifier which we can assess the practical use of the product.
Variant solutions reconstruction of airconditioning systems in the laboratory
Faltys, Michal ; Andrys, Petr (referee) ; Rubina, Aleš (advisor)
The diploma thesis deals with the designing and assessment of two variants of the reconstruction of the air conditioning system for the half of 3rd floor laboratory building BioVendor – Laboratorní medicína a.s. company. The system is proposed to fulfil hygienic, operational, economic and functional requirements for indoor microclimate of laboratories. The task of this system is the transport of fresh air to interior and the covering of heat gains in summer. The equipment is also designed for the regulation of air humidity in the interior. The theoretical part deals with the application of heat penetration of solar radiation double glazed construction. Calculating and project part deals with the specific proposal of two variants of a new HVAC system-level studies of which the selected variant is developed as the project documentation. Experimental part is devoted to measuring of CO2 concentration in operationally similar laboratory. The result of this work is to evaluate the operational and economic impacts on the choice of technically feasible options and implementation documentation selected option. The benefit of the experiment is to verify sufficient air exchange to ensure the optimum concentration of carbon dioxide in laboratories.

National Repository of Grey Literature : 12 records found   previous11 - 12  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.