National Repository of Grey Literature 45 records found  previous11 - 20nextend  jump to record: Search took 0.01 seconds. 
Experimental study of friction and lubrication in THR
Urban, Filip ; Čermák, Jan (referee) ; Vrbka, Martin (advisor)
This work analyzes problems of friction and lubrication of total hip replacement (THR). At first, experimental study of friction coefficient under various conditions was conducted using hip joint simulator based on principle of pendulum. After that, lubrication film development was observed, using colorimetric interferometry with head from THR and glass cup with respect of geometry and clearance to cups made originally for THR. With respect to research study [25] it was found that increasing contact conformity leads to increased film thickness. Also protein adsorption on articulating surfaces was observed. Thanks to adsorption 80 nm film thickness was measured even if relative surface speed was zero. Furthermore protein aggregation was observed on the border of contact zone, similar aggregations were observed by Myant et al. [29] or Vrbka et al. [25]. These aggregations are formed when lubricant is under shear stress and it can positively affect film thickness. If the relative motion of articulating surfaces is not sufficient, the protein layer can`t be refreshed enough and film thickness start decreasing. Coefficient of friction 0,13 was measured when lubricating film development was observed. Close to this value are material combinations metal on polyethylene and metal on metal.
Influence of viscosupplementation on cartilage lubrication
Ondra, Martin ; Horák, Zdeněk (referee) ; Ranuša, Matúš (advisor)
This work deal with the determination of the effect of viscosupplementation on the lubrication of articular cartilage in the beginning phase of osteoarthritis. This effect was evaluated based on the development of CoF measured by a tribometer in configuration pin-on-plate. The tribological model of incipient osteoarthritis was simulated by using two articular cartilages lubricated with osteoarthritic synovial fluid to which viscosupplementation agents were added. These preparations differed mainly in cross-linking and molecular weight of hyaluronic acid (HA). Measurements have shown that viscosupplementation may be effective in the beginning phase of osteoarthritis. The efficacy of viscosupplementation preparations with cross-linking HA was significantly higher compared to the efficacy of viscosupplementation preparations without cross-linking. These results support the use of viscosupplementation to delay the advanced stage of osteoarthritis.
Lubrication of hip joint replacements
Rebenda, David ; Hartl, Martin (referee) ; Vrbka, Martin (advisor)
This thesis deals with the experimental study of lubrication of hip joint replacements. The influence of the synovial fluid composition and the head material to the lubricating film thickness were asssesed by using a pendulum hip joint simulator. Both of these effects were assesed under static and dynamic loading conditions. The experimental results showed that the movement of the head against the cup is unnecessary for the separation of the rubbing surfaces by a layer of adsorbed proteins. Composition of the synovial fluid then significantly influences the thickness of the lubricating film. Two opposite extremes have been observed during tests with two model synovial fluids. The first fluid formed a very strong lubricating film. The second sample almost prevent adsorption of proteins and consequently formed only very thin lubricating film. The influence of the material is noticeable when comparing the results obtained with a metal head and ceramic heads. Metal head formes under the same conditions thicker lubricating film. This evidence may be partly influenced by different diametrical clearances, which were in the case of ceramic heads higher.
Friction and lubrication of fascia
Chmelík, Jiří ; Daniel, Matej (referee) ; Vrbka, Martin (advisor)
The diploma thesis was part of the project "Regeneration and lubrication of fascia with hyaluronan" of the company Contipro a.s., whose main goal is the development of an injectable medicinal product. The number of patients suffering from so-called myofascial lower back pain is increasing. The cause of the pain is increased hyaluronic acid, which is produced between the layers of the fascia. If the viscosity is low, the fascia layers are not affected and the coefficient of friction is low. The purpose of the product is to improve the sliding movement of the fascia and relieve patients of pain. The main component of the medicine is hyaluronic acid. The project included rheological and tribological analysis of hyaluronic acid samples. A tribological model of fascia in a pin-on-plate configuration was created for the analysis of the coefficient of friction. Based on the fascia models used, the dependence between the coefficient of friction and viscosity of native hyaluronic acid solutions was found. For models and real fascias, the native solution (Bonharen) was found to have better friction properties than hyaluronic acid derivatives. These analyzes have contributed not only to the development of the drug, but also to the emergence of other studies that would like to address the biotribology of fascia.
History of hip joint replacements
Kohout, Jiří ; Urban, Filip (referee) ; Vrbka, Martin (advisor)
In this bachelor´s thesis is solved problem of friction, lubrication, wear and history of hip replacement. History is described from the second half of 18th century and there was an effort to include every important milestones that affected development of the alloplastic of hip joint. Beside this development is also observed volume wear of hip joint. History of lubrication and friction is watched from first experiment, which measured these factors it means mid-20th century.
Biotribology of artificial tears for the treatment of dry eye syndrome
Černohlávek, Mikuláš ; Daniel, Matej (referee) ; Vrbka, Martin (advisor)
This master thesis is a part of the project TAČR TREND, which aim is the development of new ingredient for treatment of dry eye syndrome. Developed ingredient is derivative of hyaluronic acid, which is in this thesis compared with native hyaluronic acids and commercial eye drops. Aim of this thesis is to describe rheological and tribological properties of measured samples in terms of viscosity, mucoadhesivity and coefficient of friction. Coefficient of friction was measured on created tribological model of the eye in pin-on-plate configuration which represents physiologically relevant sliding speeds of blinking. Comparison with native hyaluronic acids and commercial products of eye drops showed, that derivative reaches higher values of viscosity, has mucoahesive properties and has low values of coefficient of friction. Those key parameters show that modification of hyaluronic acid is promising way for drug development for dry eye disease.
Lubrication of knee joint replacement
Sadecká, Kateřina ; Horák, Zdeněk (referee) ; Vrbka, Martin (advisor)
The work deals with the lubrication of total knee replacement using fluorescence microscopy method, which allows unique insight into the contact between femoral and tibial component. The aim was to determine the effect of composition of synovial fluid (i.e. albumin, -globulin, hyaluronic acid and phospholipids) on film thickness and protein behaviour in contact, and also to determine changes of contact area during rotation. Since this is the first experimental work dealing with a knee replacement lubrication primarily, only simple rotation and load cycles were applied by the knee simulator. The output of the experiments was fluorescence intensity, which corresponds to dimensionless film thickness, over time. Another important output are the images directly showing the fluorescently labelled proteins in the contact area. The results show, there are fundamental differences in lubrication in different positions of rotation, due to changes of position, shape and behaviour of the contact area. The composition of the lubricant is also essential, since the proteins themselves form a relatively strong lubricating film and their mixture leads to a substantial reduction of film thickness, due to significant formation of clusters. Complex fluid, although it does not form the strongest layer, is able to create a quite continuous film.
Experimental study of friction in articular cartilage
Praus, Tomáš ; Vrbka, Martin (referee) ; Rebenda, David (advisor)
This thesis deals with the experimental study of friction in articular cartilage. After the introduction to biotribology, there are described a principle of measurment on the Mini-Traction Machine and a brief description of machine itself. After that, there is a propose for a preparation and storage of cartilage samples, construction of the adapter into the MTM and research of the friction coefficient. The results of experimental research showed the negative effect of storing the samples in the refrigerator. On the other hand, the measurement of the friction coefficient of the samples stored in the freezer showed the preservation of the mechanical properties of cartilage. Even load and speed of loading have a big effect on friction. When the speed increases, the coefficient of the friction increases too. There is an extreme increase of the friction at higher speeds. But with increasing load the friction coefficient decreases.
The Effect of Synovial Fluid Constituents on Lubrication of Hip Joint Replacements
Nečas, David ; Daniel,, Matej (referee) ; Sawae, Yoshinori (referee) ; Hartl, Martin (advisor)
Dizertační práce se zabývá mechanismy mazání v náhradách kyčelního kloubu. Byla provedena systematická studie formování proteinového filmu při zahrnutí různých materiálů a provozních podmínek. Hlavní pozornost je přitom věnována roli jednotlivých proteinů obsažených v synoviální kapalině při současné přítomnosti dalších proteinů. Jelikož metody aplikované v předchozích studiích neumožňovaly separovat jednotlivé složky maziva, byla vyvinuta optická měřící metoda na principu fluorescenční mikroskopie. Z důvodu verifikace metody byly provedeny dvě nezávislé studie zaměřené na měření tloušťky mazacího filmu a dělení maziva na výstupu mazaného kontaktu. Z důvodu určitých limitací fluorescenční mikroskopie byla dále využita i metoda optické interferometrie, jejíž využití je ilustrováno ve studii zabývající se formováním mazacího filmu v náhradách kyčelního klubu při uvažování reálné konformity třecích povrchů. Závěrečná část práce představuje nový metodologický přístup založený na in situ pozorování kontaktní oblasti umožňující popsat roli jednotlivých proteinů ve vztahu k vývoji tloušťky mazacího filmu. Práce obsahuje originální výsledky, které přináší nové poznání v oblasti biotribologie náhrad kyčelního kloubu vedoucí k dalšímu vývoji implantátů při snaze zabránit jejich selhání v důsledku omezené životnosti.
Study of Friction in Hip Joint Replacements
Balounová, Hana ; Dzimko, Marián (referee) ; Vrbka, Martin (advisor)
Diploma thesis deals with analysis of coefficient of friction in total hip prosthesis for several materials bearing with presence of bovine serum as substitute of synovial fluid occurred in natural joint. Behavior of coefficient of friction is observed on Mini Traction Machine. Results are plotted at graphs representing dependence of coefficient of friction on time. There are described effects of several kinematic conditions, the influence of used material and the effect of the method of contact lubrication. The experiments analyze how the formation of lubricant film with a layer of adsorbed protein affects coefficient of friction.

National Repository of Grey Literature : 45 records found   previous11 - 20nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.