Residual stress determination in EUCOR ceramics plasmatic coating
Fuis, Vladimír ; Janíček, P. ; Vlk, M.
The paper presents results of residual stress determination in EUCOR ceramics plasmatic coating. The coating was performed on steel test sample and test sample of casted EUCOR ceramics. Hole drilling method has been used. Residual compressive stress occurs in EUCOR plasmatic coating coated on steel sample, residual tensile stress occurs in coating on casted EUCOR.
Abrasive and cavitation deterioration of thin layers of EUCOR ceramics
Pešlová, F. ; Janíček, P. ; Filípek, J. ; Fuis, Vladimír
The authors present the results of measuring the abrasive and cavitation deterioration of EUCOR ceramics plasmatic coating. Three methods were used for determination of the resistance against abrasive deterioration: method of rotating sample in rotating abrasive, method of abrasive cloth and method of rotating sample in rotating abrasive in cylindrical grinding container.