National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
Suppression of powerline interference in ECG signals
Lacko, Michal ; Hrubeš, Jan (referee) ; Kozumplík, Jiří (advisor)
This project includes survey of various methods ECG signal filtering, to suppress of powerline interference. It is specialized especially on properties which affecting the quality of filtration. The main essence of project is evaluation of the proposed methods in terms of quality and the least possible distortion of the resulting ECG signal. The work is focused on linear, adaptive filtering and filtering using discrete wavelet trans-form. Signal processing and evaluation of descriptive parameters are transferred using the graphical interface GUI in the program Matlab 7.7.0 ( R2008b ).
Measurement of the properties of operation amplifier
Lacko, Michal ; Sekora, Jiří (referee) ; Kolář, Radim (advisor)
This thesis includes a survey of operation amplifiers used for biological signal measurement. The first part is focused on the description of amplifier’s properties which are important in biomedical engineering. The next part describes several applications (virtual instruments) which measure selected properties. These applications are created with the help of the programming environment LabView 7.1, the measuring card NI PCI-6221 and a suggested product. The project includes four applications: measuring of frequency characteristics, automated measuring of frequency characteristics, measuring of input offset voltage, and measuring of common-mode rejection.
Studies of reactions of ions with water molecules in the gaseous phase for trace gas analysis
Lacko, Michal ; Španěl, Patrik (advisor) ; Milosavljevič, Aleksandar (referee) ; Poterya, Viktoriya (referee)
Chemical ionization mass spectrometry (CI-MS) is a powerful analytical technique, capable to detect trace levels of organic molecules diluted in air samples in real-time. Processes leading to ionization of organic molecules, necessary for their detection and identification, are however often strongly affected by the presence of water vapours in form of sample humidity. In the present work, I studied the influence of water vapours on ion chemistry and, subsequently, the respective influence on sensitivity and selectivity of CI-MS techniques. Studies were carried out using several soft chemical ionization mass spectrometry instruments, including Selected Ion Flow Tube Mass Spectrometry (SIFT-MS), Proton Transfer Reaction Mass Spectrometry (PTR-MS) and Selected Ion Flow-Drift Tube Mass Spectrometry (SIFDT-MS). Experimental studies were also supplemented by theoretical simulation of proposed ion chemistry using the Kinetic of Ion-Molecular Interaction simulator (KIMI), developed by the author. In this thesis, I present a study of formaldehyde, glyoxal and phthalates ion chemistry with H3O+ , NO+ and O2 + reagent ions, focusing on secondary reactions with water vapours. Additionally, I also studied secondary reactions of protonated hydrated acetic acid with acetone. Finally, I have carried out...
Studies of reactions of ions with water molecules in the gaseous phase for trace gas analysis
Lacko, Michal ; Španěl, Patrik (advisor)
Chemical ionization mass spectrometry (CI-MS) is a powerful analytical technique, capable to detect trace levels of organic molecules diluted in air samples in real-time. Processes leading to ionization of organic molecules, necessary for their detection and identification, are however often strongly affected by the presence of water vapours in form of sample humidity. In the present work, I studied the influence of water vapours on ion chemistry and, subsequently, the respective influence on sensitivity and selectivity of CI-MS techniques. Studies were carried out using several soft chemical ionization mass spectrometry instruments, including Selected Ion Flow Tube Mass Spectrometry (SIFT-MS), Proton Transfer Reaction Mass Spectrometry (PTR-MS) and Selected Ion Flow-Drift Tube Mass Spectrometry (SIFDT-MS). Experimental studies were also supplemented by theoretical simulation of proposed ion chemistry using the Kinetic of Ion-Molecular Interaction simulator (KIMI), developed by the author. In this thesis, I present a study of formaldehyde, glyoxal and phthalates ion chemistry with H3O+ , NO+ and O2 + reagent ions, focusing on secondary reactions with water vapours. Additionally, I also studied secondary reactions of protonated hydrated acetic acid with acetone. Finally, I have carried out...
Measurement of the properties of operation amplifier
Lacko, Michal ; Sekora, Jiří (referee) ; Kolář, Radim (advisor)
This thesis includes a survey of operation amplifiers used for biological signal measurement. The first part is focused on the description of amplifier’s properties which are important in biomedical engineering. The next part describes several applications (virtual instruments) which measure selected properties. These applications are created with the help of the programming environment LabView 7.1, the measuring card NI PCI-6221 and a suggested product. The project includes four applications: measuring of frequency characteristics, automated measuring of frequency characteristics, measuring of input offset voltage, and measuring of common-mode rejection.
Suppression of powerline interference in ECG signals
Lacko, Michal ; Hrubeš, Jan (referee) ; Kozumplík, Jiří (advisor)
This project includes survey of various methods ECG signal filtering, to suppress of powerline interference. It is specialized especially on properties which affecting the quality of filtration. The main essence of project is evaluation of the proposed methods in terms of quality and the least possible distortion of the resulting ECG signal. The work is focused on linear, adaptive filtering and filtering using discrete wavelet trans-form. Signal processing and evaluation of descriptive parameters are transferred using the graphical interface GUI in the program Matlab 7.7.0 ( R2008b ).