National Repository of Grey Literature 53 records found  beginprevious33 - 42nextend  jump to record: Search took 0.00 seconds. 
Stress-Strain Analysis of Total Endoprosthesis of Temporomandibular Joint
Horňas, Jan ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
The presented master’s thesis deals with the problem of the application of total endoprosthesis (TEP) during temporomandibular joint (TMJ) replacement. The implantation of TEP occurs due the severe TMJ disease (arthrosis, ankylosis, cancer) or its macrotrauma. Condylar prosthesis is fixed during the implantation by self-tapping screws to the mandible. This fixation causes a change of stress-strain behaviour of mandible, TEP and fixation screws. In the thesis is performed the stress-strain analysis by using computational modeling in use the finite element method (FEM). Analysis is performed for six different screws positions (the number of screws is unchanged) and for a variable the static friction coefficient (in range 0.1 to 0.11) between condylar prosthesis (CP) and fossa prosthesis (FP). Altogether, 36 variants of computational models were created. The stress strain analysis detected a substantial influence of the static friction coefficient value to final results of displacements, contact pressure on the articulation surface between the CP and the FP and also to von Mises stress of the CP. A substantial influence of different screws position is detected for von Mises stress in the screws and for von Mises strain in the cortical and spongious bone tissue.
Stress-Strain Analysis of Mandible with Fixator
Semerák, Jaroslav ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
This diploma thesis deals with fixation of the lower jaw fractures using commercially produced fixators. The topic was researched on the basis of the available literature. The thesis also indicates basic anatomy of the surveyed area and nowadays the most commonly used materials. Subsequently, the stress-strain analysis of the lower jaw with the applied angular stable fixation plate was performed. The solution was performed for the lower jaw with a fracture in the area of the condyle with different types of fixation plates made of CP-Ti Grade 4. In addition, the strain analysis of the healed lower jaw with the fixators after the defect in the area of chin and angle was performed. The mechanical interaction analysis of the lower jaw with defect and applied fixation plate was solved by using computational modeling with variational approach, in use of the finite element method in Ansys Workbench 18.1. The thesis also describes in detail the creation of a computational model of the system and the subsequent solution.
Stress-strain analysis of screw-bone system used in a plate-fixation of fractures
Kalnický, Jakub ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
In the field of orthopaedics and traumatology, a whole series of problems appear related to fracture fixation by means of various types of plates. Appropriate application of the plate is the difficult task that a doctor needs to deal with in the operating room. Regarding mechanics, the number of screws and their spacing have a major impact on the healing process. If there are too many screws or lack of them, the fracture does not heal properly. This can lead to implant failure. This work deals with stress-strain analysis of screws and bone tissue with a fracture fixed by LCP. It deals with the influence of different geometrical configurations of the screws on the stress, deformation and strain of the system. For this purpose, the computational modelling was used by means of the finite element method. Two computational models have been created, on which different screw arrangement was analysed. The first computational model represents diaphysis of the femur that is at the beginning of the healing process. For the four load models and eleven geometric configurations and number of the screws, a total of 44 computations were performed. The second computational model represents the distal part of the femur. Femoral geometry model was created based on CT (computed tomography) examination, geometric model of the plate was created by 3D scanning. Deformations and stresses were compared in the three geometric configurations of the screws during the healing process.
Stress-strain analysis of mandible with applied fixator due to the missing bone tissue
Fňukal, Jan ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
This thesis deals with the fixation of lower jaw with bone tissue defect using commercially produced fixator. Large defects of bone tissue are mainly caused due to the removal of bone tissue affected by tumor. These topics have been researched on the basis of the literature. Subsequently, stress strain analysis of the lower jaw with the applied fixation plate was performed. This analysis was solved by using computational modeling with variational approach, ie the finite element method. The work also describes in detail the procedure of creating model of geometry, model of material, model of boundary conditions and loads with subsequent solution of several computational models. The stress strain analysis was done for lower jaw with varying size of the removed bone tissue with applied reconstruction plate made of CP-Ti Grade 4 and for the lower jaw with the plate, which is made of -Ti-Mo. Finally, the influence of the mechanical properties of the callus during formation of new bone tissue (callus healing) on the stress and deformation of the solved system was evaluated.
Biomechanical Studies of Facial Bone
Valášek, Jiří ; Janíček, Přemysl (referee) ; Horyl, Petr (referee) ; Florian, Zdeněk (advisor)
Presented work deals with Biomechanical study of the facial skeleton. This work is focused on the fixation of the mandible after removal of a tumor from affected bone tissue. The aim of the work is to perform biomechanical study of the facial skeleton with subsequent detailed stress strain analysis of two mandible implants designed and manufactured for specific patients. The geometry model of mandible used for design of mandible implants and used for computational modelling has been obtained on the basis of CT data of two patients. A Theoretical-Clinical sub-study that deals with the comparison the CT data processing which is necessary for creating the model of geometry is a part of the thesis. Two models of mandible with applied mandible implant have been created for two specific patients with tumorous mandible bone tissue. Stress strain analysis has been performed for these two models. Results of the stress strain analysis of two models of mandibles with mandible implants are presented in the final chapters of the thesis. Findings of the biomechanical study have been published and applied in clinical practice.
Biomechanical studies of facial bone
Valášek, Jiří ; Florian, Zdeněk (advisor)
Presented work deals with Biomechanical study of the facial skeleton. This work is focused on the fixation of the mandible after removal of a tumor from affected bone tissue. The aim of the work is to perform biomechanical study of the facial skeleton with subsequent detailed stress strain analysis of two mandible implants designed and manufactured for specific patients. The geometry model of mandible used for design of mandible implants and used for computational modelling has been obtained on the basis of CT data of two patients. A Theoretical-Clinical sub-study that deals with the comparison the CT data processing which is necessary for creating the model of geometry is a part of the thesis. Two models of mandible with applied mandible implant have been created for two specific patients with tumorous mandible bone tissue. Stress strain analysis has been performed for these two models. Results of the stress strain analysis of two models of mandibles with mandible implants are presented in the final chapters of the thesis. Findings of the biomechanical study have been published and applied in clinical practice.
Stress and strain analysis of skull implant
Chamrad, Jakub ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
To, jak se bude implantát chovat v lebce, je velmi důležitým faktorem, který ovlivňuje jeho funkci. K ovlivnění dochází především vnějšími silami a nitrolebečním tlakem. Tato zatížení mohou způsobit pohyb implantátu a poškození živých tkání. Tato práce shrnuje poznatky a analýzy, týkající se rekonstrukce poranění lebky. Srovnání implantátů z různých materiálů a fixátorů je založené na napěťově-deformační analýze implantátu, zatíženého vnějšími silami a nitrolebečním tlakem.
Biomechanical research study of skull plates and implants
Vystrk, Tomáš ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
Cranial implants along with fixators are used to restore the function of the damaged area of the human skull, where due to disease or injury the defect was created. When assessing the suitability of the implant and fixators the mechanical properties are significant. With this the material and shape of implant and fixators are related. The implant must be suitable with human bone tissue and also be able to withstand long-term loading. This paper summarizes the present knowledge regarding the design, manufacture and application of cranial implants. Next the stress-strain analysis of the loaded scull with irregular shaped defect, placed implant and fixation system is provided.
Stress-strain Analysis of Dental Veneers
Valenta, Jiří ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
This thesis focuses on stress-strain analysis of the upper central incisor with applied veneer and its variations with proximal fillings and endodontic treatment. The basic materials and veneer types are introduced at the beginning. Next chapter describes the creation of geometric models of a healthy tooth, veneers and fillings. The veneer geometry model has been done in several variants, taking different thickness values, veneer ranges and used materials into account. A finite element mesh was applied to the models. The computation model was solved using the finite element method using the ANSYS 14.0 software in the Workbench graphics environment. The results of the analysis show that the composite material is more suitable for veneers placed partially in the dentin - either with proximal fillings or without them. The ceramic material is a better option for endodontic treatment. Veneers located in the enamel are not significantly affected by the choice of material and the ceramic material is more appropriate only when proximal fillings are applied.
Stress-strain Analysis of Chosen Spinal Fixation Device
Prášilová, Eva ; Valášek, Jiří (referee) ; Marcián, Petr (advisor)
The degenerative and traumatic injuries of a spine are very frequent. In those cases it is necessary to stabilize the corresponding spine segment using a spine implant. The spinal implants are rigid or flexible, the latter known as dynamic ones in medical practice. In this thesis, the problems of the physiological spinal segment and the segment with implant were solved using the computational modelling (finite element method). Computational model consists of 4 lumbar vertebrae L2 – L5, intervertebral discs, joints and spinal implants. The spinal segment was loaded by the force 400N and 200N, than by force 200N together with bending moments 2,5Nm and 5Nm depending of the motion. The displacement of the whole system, contact pressure of cartilages, equivalent strain in cancellous bone and equivalent stress in the implant were analyzed. The deformation of the physiological model and the model with the implant are comparable, but the bone tissue of the model with the implant is dramatically more loaded in vicinity of the screws.

National Repository of Grey Literature : 53 records found   beginprevious33 - 42nextend  jump to record:
See also: similar author names
3 Valášek, J.
4 Valášek, Jakub
5 Valášek, Jan
5 Valášek, Ján
Interested in being notified about new results for this query?
Subscribe to the RSS feed.