National Repository of Grey Literature 192 records found  beginprevious189 - 192  jump to record: Search took 0.01 seconds. 
Model for the Cable Thermal Characteristic Calculation
Starý, Zdeněk ; Drápela, Jiří (referee) ; Orságová, Jaroslava (advisor)
The result of this assignment is the Model for the Cable Thermal Characteristic Calculation. Firstly, there is a prepared overview that is focused on the essential ideas of cable technology. The following part describes the simple possibilities of passaging the heat. Secondly,the physical essence of warming cables as well as the possibility to discover the methods how to calculate the warming cables are also mentioned in this task.There is an opportunity to find the methods for calculating the warming cables as well. The model was verificationed in the conclusion of my assignment. The measurement was done and the empirical results were compared with the results that were achieved by modeling.
Regulation of Pumped Storage Power Plants Inputs Under the Pumped Operating Condition.
Lorenz, Tomáš ; Cink, Aleš (referee) ; Orságová, Jaroslava (advisor)
This paper focuses on the Double Fed Induction Machine in the Pumped Storage Power Plants. It includes listing of this plants in the world, where such a technology is used; principle of Double Fed Induction Machine, its usage with variable speed, advantages and disadvantages and also experience of its usage.
Project of Earthing System in 110/22 kV Transfornmation Station
Pavlík, Ludvík ; Procházka, Aleš (referee) ; Orságová, Jaroslava (advisor)
This Thesis is concerned with the concept of grounding of 110/22 kV transformer station. The aim of the Thesis is to create a ground network for grounding a specified outdoor substation. This 110 kV outdoor substation is formed according to H-scheme and encircles a wide area. In additon to this, an earth potential has to be distributed as equally as possible within the whole area of the substation. The most convenient alternative from the point of view of effective grounding and distribution of potential is a grid network. Therefore, the grid network is the means of grounding which I have chosen as a solution for this issue. In this solution, flat conductor network cables are used to cover the whole substation, with ground rods placed at the points of intersection. Parts of appliance can be then connected to this existing network, thus creating several parallel channels which provide grounding with low resistance. The network is made of common steel zinc-coated stip, size 30 x 4 mm. When proposing a concept of grounding and adjustment of ground electrodes, we have to take account of grounding requirements, stated according to ČSN standards. The proposed earthing system was created in appropriate size in order to meet all these grounding requirements. These requirements are also mentioned and described in a theoretical part of the Thesis. Second part of the Thesis consists of proposed concept of the grounding itself, together with calculated parameters. The grounding has to be carried out according to both safety regulations and electrical appliance requirements. The issue of grounding substations of power system is resolved by the ČSN standards 33 3201 (“Elektrické instalace nad AC 1kV”), 33 2000-4-41 (“Elektrická zařízení – Ochrana před úrazem elektrickým proudem”) and 33 2000-5-54 (“Elektrická zařízení – Výběr a stavba elektrických zařízení – Uzemnění a ochranné vodiče”) and by the PNE company standards 33 0000-4 (“Příklady výpočtů uzemňovacích soustav v distribuční a přenosové soustavě dodavatele elektřiny”) and 33 0000-1 (“Ochrana před úrazem elektrickým proudem v distribuční soustavě dodavatele elektřiny”). These standards apply to creating a concept of grounding and grounding of new, reconstructed or expanded electrical substations of power system.
Conventional and Unconventional Solving of 123 kV Outdoor Switchgears
Petrucha, Lukáš ; Pisarčík, Tomáš (referee) ; Orságová, Jaroslava (advisor)
This graduation theses shows some of possible versions of outdoor switchgears with very high voltage, especially on the level 123 kV both concerning own complement of classic outdoor switchgears with devices as are overvoltages limiter, disconnecting switchgears, circuit breakers, etc., and compact connections. In the introduction of my theses there are explained basic ideas and theories of switchgears and described main devices and equipments which create classic (from equipment setting point of view) outdoor switchgears of very high voltage. Subsequently it describes possible ways of linking-up of these devices in the complex of switchgears themselves according to possible dispositions arranged and busbars systems. The same focus is dedicated to new, non-classic (non-standard solution in terms of devices solution), compact solving of outdoor very high voltage modules either by air isolated or by means of enclosed technology with gas SF6 which represent innovative solving first of all from reduction of built up area point of view which is very important from economic point of view especially during constructions of new switchgears. In the end of my theses there are mentioned also brief evaluations of producers and economics for development and operation of individual technologies. I used for my work materials of companies CEZ, a. s., Siemens, a. s. and Abb, a.s.

National Repository of Grey Literature : 192 records found   beginprevious189 - 192  jump to record:
See also: similar author names
1 ORSÁGOVÁ, Jana
Interested in being notified about new results for this query?
Subscribe to the RSS feed.