Steady state and short-circuit conditions within E.ON 110kV power network at bridge operation of transformers T401 and T402 in 400/100kV transformer station Čebín
Klobučník, Jozef ; Janda, Petr (referee) ; Blažek, Vladimír (advisor)
Master’s thesis deals with computation of steady state and short-circuit conditions in the 110 kV distribution network in the nodal area of Čebín. Computations are done during independent operation and bridge operation of transformers T401, T402 in transformation station Čebín with proposed configuration of network. Additional computations of steady state during specific operating conditions such as (T401 outage, disconnection of line 5553) were done during network operation in bridge operation of T401, T402. Voltage conditions in substations, load of 110kV lines and 400/110 kV, 110/HV kV transformers are evaluated based on the computations of steady state. Short-circuit resistance of substations is being evaluated with the aid of calculations of short-circuit conditions. There is a comparison and processed results of computations during independent operation, bridge operation, special operational states and proposed technical measures of operation in bridge operation in the end of the thesis. Theoretical part of the master’s thesis deals with the description of 110 kV distribution networks, theory of calculation of the steady state of electric system with the aid of Newton iterative method a calculation of single-phase and three-phase short-circuit current with the aid of method of symmetrical components.
Steady state and short-circuit conditions within E.ON 110kV power network at bridge operation of transformers T401 and T402 in 400/100kV transformer station Čebín
Klobučník, Jozef ; Janda, Petr (referee) ; Blažek, Vladimír (advisor)
Master’s thesis deals with computation of steady state and short-circuit conditions in the 110 kV distribution network in the nodal area of Čebín. Computations are done during independent operation and bridge operation of transformers T401, T402 in transformation station Čebín with proposed configuration of network. Additional computations of steady state during specific operating conditions such as (T401 outage, disconnection of line 5553) were done during network operation in bridge operation of T401, T402. Voltage conditions in substations, load of 110kV lines and 400/110 kV, 110/HV kV transformers are evaluated based on the computations of steady state. Short-circuit resistance of substations is being evaluated with the aid of calculations of short-circuit conditions. There is a comparison and processed results of computations during independent operation, bridge operation, special operational states and proposed technical measures of operation in bridge operation in the end of the thesis. Theoretical part of the master’s thesis deals with the description of 110 kV distribution networks, theory of calculation of the steady state of electric system with the aid of Newton iterative method a calculation of single-phase and three-phase short-circuit current with the aid of method of symmetrical components.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.