QRS complex detection in multilead ECG signals
Šlancar, Matěj ; Smital, Lukáš (referee) ; Kozumplík, Jiří (advisor)
The aim of this thesis is to introduce the principles of software QRS detection, which is based on different combinations of orthogonal (pseudoorthogonal) leads. The thesis describes the main components of the ECG signal, a selection of methods that can be used for QRS detection in orthogonal leads and finally the evaluation of the effectiveness of the chosen methods and a comparing the approaches with the results of other authors. Functionality of detection algorithm has been tested on signals of CSE standard library.
A Wavelet-Based QRS-Complex Detection
Kocian, Ondřej ; Provazník, Ivo (referee) ; Kozumplík, Jiří (advisor)
This project investigates methods of construction the wavelet-based QRS-complex detector. QRS-complex detection is very important, because it helps automatically calculate heart rate and in some cases it is used for compression ECG signal. The design of QRS detector can be made with many methods, in this project were mentioned and consequently tested only a few variants. The principle of designed detector used a wavelet-based decomposition of the original ECG signal to several frequency-coded bands. These bands are consequently transformed to absolute values and with the help of the threshold value are marked positions of assumed QRS complexes. Then are these assumed positions from all bands compared between themselves. If the position is confirmed at least at one nearby band, then is this position marked as true QRS complex. To increase efficiency of designed detector, two modifications were additionally mentioned. The first one, using the envelope of the signal, had rather negative effect on detectors efficiency. The second modification, using combined signal from three pseudoorthogonal leads, had reversely very good effect on detectors efficiency. In the end, the designed detector and all its modifications were tested on signals from CSE library (exactly on leads II, V2 and V6).
Detection of QRS complexes in multilead ECG signals
Dufková, Barbora ; Němcová, Andrea (referee) ; Kozumplík, Jiří (advisor)
The aim of this thesis is to acquaint the reader with the basic methods of QRS detection in a multilead ECG signals and with the possibilities of implemetation of these methods in Matlab. Firstly, the methods of signal preprocessing, which are based on orthogonal and pseudoorthogonal leads, are described. Then there are described some implemented and also some more advanced unrealized methods.The implemented methods are tested on the CSE database. The last part of the work is a comparison with the results of other authors who also tested their algorithms on the CSE database.
Detection of QRS complexes in multilead ECG signals
Dufková, Barbora ; Němcová, Andrea (referee) ; Kozumplík, Jiří (advisor)
The aim of this thesis is to acquaint the reader with the basic methods of QRS detection in a multilead ECG signals and with the possibilities of implemetation of these methods in Matlab. Firstly, the methods of signal preprocessing, which are based on orthogonal and pseudoorthogonal leads, are described. Then there are described some implemented and also some more advanced unrealized methods.The implemented methods are tested on the CSE database. The last part of the work is a comparison with the results of other authors who also tested their algorithms on the CSE database.
QRS complex detection in multilead ECG signals
Šlancar, Matěj ; Smital, Lukáš (referee) ; Kozumplík, Jiří (advisor)
The aim of this thesis is to introduce the principles of software QRS detection, which is based on different combinations of orthogonal (pseudoorthogonal) leads. The thesis describes the main components of the ECG signal, a selection of methods that can be used for QRS detection in orthogonal leads and finally the evaluation of the effectiveness of the chosen methods and a comparing the approaches with the results of other authors. Functionality of detection algorithm has been tested on signals of CSE standard library.
A Wavelet-Based QRS-Complex Detection
Kocian, Ondřej ; Provazník, Ivo (referee) ; Kozumplík, Jiří (advisor)
This project investigates methods of construction the wavelet-based QRS-complex detector. QRS-complex detection is very important, because it helps automatically calculate heart rate and in some cases it is used for compression ECG signal. The design of QRS detector can be made with many methods, in this project were mentioned and consequently tested only a few variants. The principle of designed detector used a wavelet-based decomposition of the original ECG signal to several frequency-coded bands. These bands are consequently transformed to absolute values and with the help of the threshold value are marked positions of assumed QRS complexes. Then are these assumed positions from all bands compared between themselves. If the position is confirmed at least at one nearby band, then is this position marked as true QRS complex. To increase efficiency of designed detector, two modifications were additionally mentioned. The first one, using the envelope of the signal, had rather negative effect on detectors efficiency. The second modification, using combined signal from three pseudoorthogonal leads, had reversely very good effect on detectors efficiency. In the end, the designed detector and all its modifications were tested on signals from CSE library (exactly on leads II, V2 and V6).