National Repository of Grey Literature 112 records found  beginprevious21 - 30nextend  jump to record: Search took 0.01 seconds. 
Industrial Building - Review of Selected Reinforced Concrete Parts
Weber, Jozef ; Zlámal, Martin (referee) ; Švaříčková, Ivana (advisor)
Bachelor’s thesis deals with reinforced concrete floor structure. It is a 3D frame, which is composed of bar elements oriented in the longitudinal and transverse direction. The work is done calculating mean longitudinal beam and also the middle of the cross beam. Furthermore, the calculated floor structure, which operates in both directions. For the calculation of inner strength used computer program SCIA ENGINEER 2013.0, which operates on the Finite Element Method - FEM. All elements have been designed for ultimate and serviceability limit state. Work contains textual part, inner strength, static calculations, drawings and used documents.
Design of prestressed bridge structure
Otáhal, Ondřej ; Rybák, Vít (referee) ; Klusáček, Ladislav (advisor)
Diploma thesis deals with design of a road bridge over Husí potok in Hladké Životice. The supporting structure of the bridge is designed in three variants, one of which is selected variant post-tensioned slabs. To address the internal forces is used computing software Scia Engineer. In the structural analysis of the bridge structure is assessed at the ultimate limit state and serviceability by European standards – Eurocodes. For chosen variant is prepared drawing documentation and visualization.
Reinforced concrete slab supported on columns
Hadamíková, Karolína ; Strnad, Jiří (referee) ; Požár, Michal (advisor)
The bachelor thesis is focused on design and assessment point-supported slab on the lowest level of fourth-level storage to ultimate and serviceability limit state. Design of slab was created in software SCIA Engineer and followed by checking if it is right by manual calculation. This thesis contains a static calculation and technical drawings of typical column, foundation pad. At the end of structural assessment was calculated prefabricated staircase. All structures were proceeded according to the valid standard ČSN EN 1992-1-1.
Reinforced concrete structure of a multifunction building
Marková, Anna ; Buřič, Pavel (referee) ; Šulák, Pavel (advisor)
The aim of this qualification thesis is to design a reinforced concrete monolithic ceiling construction of typical floor. It concerns locally supported panel that is 250 mm thick and of irregular shape. The spread of the span is 6 x 6 m with the overshoot of 1,2 m. Inside the building there is a staircase with a lift and a plumbing stack that is surrounded by the monolithic reinforced concrete wall that is 300 mm thick. The structural height of the floor is 3500 mm. The pillars` cross-sections are 450/450 mm. An analysis using the end-element method, a static design and a drawing documentation of the ceiling panel were conducted within this thesis.
Design of structure for football pitch
Popovič, Tomáš ; Sliwka, Pavel (referee) ; Zich, Miloš (advisor)
This diploma thesis deals with the static review of structure for a football pitch. It is crosswise prestressed reinforced sliding plate with variable cross section. Assessment of the elements was done according to limit states. Internal forces from the load effects were calculated using the SW SciaEngineer 2015.1. The elements were assessed by SW Idea StatiCa 6. The main outputs of this static calculation are drawings of the shape and drawings of the reinforcement.
Static solution of a monolithic structure of an office building
Friedová, Lenka ; Kostiha, Vojtěch (referee) ; Zlámal, Martin (advisor)
The master thesis is focused on the design and assessment of the monolithic structure of an office building, respectively their main parts - slab, span, columns and basement wall. The static solution is performed in the SCIA Engineer 20.0.2028 computer program. The output of the thesis is a static calculation and drawing part, which is processed in AutoCAD software.
Reinforced concrete construction of apartment building
Fusek, Aleš ; Kalenda, Jan (referee) ; Perla, Jan (advisor)
This diploma thesis deals with the analysis of reinforced concrete structure with masonry walls. Scia Engineer was used for finite element analysis. The spatial models include nonlinear behavior of masonry. Furthermore, the ceiling slab above the 1st floor, beams and columns were designed.
Load bearing structure of multifunctional house
Strnad, Stanislav ; Šiška, Radek (referee) ; Strnad, Jiří (advisor)
Subject of this diploma thesis is to design structural system of multifunctional building in Brno. This apartment building has 4 storey. Main load-bearing elements are concrete ceilings, columns and beams in first and second storey. In third and fourth storey are main load-bearing elements masonry and concrete ceilings with beams. Also there is prestressed beam in first storey. The structure was assessed for ultimate and serviceability limit state acording to standarts and regulation. Drawings and drawings of construction are part of the diploma thesis.
Reconstruction of the Bridge over the River Moravice
Čtvrtlík, Libor ; Svoboda, Adam (referee) ; Klusáček, Ladislav (advisor)
The aim of the bachelor thesis was designing new loadbearing structure for existing bridge conctruction. From three possible options was selected one, which represents cast-in-place prestressed concrete slab. Design procedures and assessments were performed to comply with the ultimate and serviceability limit state according to valid European standards. The calculation was performed in software SCIA Engineer 17.1 that was partly checked by hand-done calculation. The part of this thesis is also enclosed drawings and visualizations.
Resistance of the roof structure loaded with photovoltaic panels
Holoubek, Jan ; Bažant,, Zdeněk (referee) ; Strnad, Jiří (advisor)
The aim of the thesis is to verify the resistance of the roof structure loaded with photovoltaic panels. On the roof of industrial building of rectangular plan with dimensions of 26,5 x 24,5 m in Hlinsko, the investor decided to install photovoltaic panels. Preliminary diagnostic survey showed only flexural reinforcement in the field of all considered load-bearing elements. Bending strength was assessed by these structural elements: reinforced concrete slab, reinforced concrete beam, reinforced concrete grinder. Static calculation includes a minimum reinforcement of support and necessary shear reinforcement, which must be demonstrated by a detailed diagnostic survey. The structural analysis includes the assessment of reinforced concrete beam deflection after loading. All assessments were performed according to currently valid Eurocodes. The calculation showed that all supporting elements meet the bending resistance and deflection of the beam is smaller than the limit value laid down in the EC, so the roof of the hall can be loaded with photovoltaic panels.

National Repository of Grey Literature : 112 records found   beginprevious21 - 30nextend  jump to record:
Interested in being notified about new results for this query?
Subscribe to the RSS feed.