National Repository of Grey Literature 4 records found  Search took 0.01 seconds. 
Assessment of cooling and heating factor of real heat pump
Tupcová, Tereza ; Andrys, Petr (referee) ; Rubina, Aleš (advisor)
The diploma thesis deals with the issue of replacement of non-ecological refrigerant R22 according to the requirements of relevant juristic regulations and of subsequent influence of this replacement to the efficiency of air conditioning systems. The theoretical part is focused on proceeding processes in thermodynamic cycles and during heat transfer, then determines calculation of cooling and heating factor in context with experimental measurement. The experimental measurement utilizes to the assessment of operation of heat pump after refrigerant replacement and it is source for the composion of economical evaluation of alternative solutions due to the particular choice of refrigerant replacement.
Airconditioning for multistorey detached house
Tupcová, Tereza ; Blasinski, Petr (referee) ; Rubina, Aleš (advisor)
The bachelor’s thesis deals with design of airconditioning systems for living rooms in multistorey detached house. The design is made to fullfill functional, hygienic and operational ruqirements for the microclimate of interier. The main task of airconditioning systems is to cover heat losses in the winter, heat gains in the summer and intake of requirement minimum of fresh air. The theoretical part deals with acoustics, mainly with sound transmition and possibilities of reduction sound intensity in rational way or by physical-technical device. The practical part includes design of two airconditioning systems of hot air rating and climatization for detached house. The result of the work is the implementing documentation of two airconditioning systems for the object.
Assessment of cooling and heating factor of real heat pump
Tupcová, Tereza ; Andrys, Petr (referee) ; Rubina, Aleš (advisor)
The diploma thesis deals with the issue of replacement of non-ecological refrigerant R22 according to the requirements of relevant juristic regulations and of subsequent influence of this replacement to the efficiency of air conditioning systems. The theoretical part is focused on proceeding processes in thermodynamic cycles and during heat transfer, then determines calculation of cooling and heating factor in context with experimental measurement. The experimental measurement utilizes to the assessment of operation of heat pump after refrigerant replacement and it is source for the composion of economical evaluation of alternative solutions due to the particular choice of refrigerant replacement.
Airconditioning for multistorey detached house
Tupcová, Tereza ; Blasinski, Petr (referee) ; Rubina, Aleš (advisor)
The bachelor’s thesis deals with design of airconditioning systems for living rooms in multistorey detached house. The design is made to fullfill functional, hygienic and operational ruqirements for the microclimate of interier. The main task of airconditioning systems is to cover heat losses in the winter, heat gains in the summer and intake of requirement minimum of fresh air. The theoretical part deals with acoustics, mainly with sound transmition and possibilities of reduction sound intensity in rational way or by physical-technical device. The practical part includes design of two airconditioning systems of hot air rating and climatization for detached house. The result of the work is the implementing documentation of two airconditioning systems for the object.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.