Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
Němečková-Makrlíková, Anna ; Matysik, F.-M. ; Navrátil, Tomáš ; Barek, J. ; Vyskočil, V.
Three tumor biomarkers (homovanillic acid, vanillylmandelic acid, and 5-hydroxyindole-3-acetic acid) have been determined by flow injection analysis with amperometric detection at screen-printed carbon electrodes in optimum medium of Britton-Robinson buffer (0.04 mol l(-1), pH = 2.0). Dependences of the peaks current on the concentration of biomarkers were linear in the tested concentration region from 0.05 to 100 mu mol l(-1), with the limits of detection of 0.065 mu mol l(-1) for homovanillic acid, 0.053 mu mol l(-1) for vanillylmandelic acid, and 0.033 mu mol l(-1) for 5-hydroxyindole-3-acetic acid (calculated from heights), and 0.024 mu mol l(-1) for homovanillic acid, 0.020 mu mol l(-1) for vanillylmandelic acid, and 0.012 mu mol l(-1) for 5-hydroxyindole-3-acetic acid (calculated fromareas), respectively.
Voltammetric Determination of Tumor Biomarkers using Flow Injection Analysis with Amperometric Detection
Makrlíková, Anna ; Matysik, F.-M. ; Barek, J. ; Vyskočil, V.
Three tumor biomarkers (homovanillic acid, vanillylmandelic acid,\nand 5-hydroxyindole-3-acetic acid) have been determined by flow\ninjection analysis with amperometric detection at screen-printed\ncarbon electrodes in optimum medium of Britton-Robinson buffer\n(0.04 mol l-1, pH = 2.0). Dependences of the peaks current on the\nconcentration of biomarkers were linear in the tested concentration\nregion from 0.05 to 100 mu mol l-1, with the limits of detection of\n0.065 mu mol l-1 for homovanillic acid, 0.053 mu mol l-1 for vanillylmandelic\nacid, and 0.033 mu mol l-1 for 5-hydroxyindole-3-acetic acid (calculated\nfrom heights), and 0.024 mu mol 1-1 for homovanillic acid,\n0.020 mu mol l-1 forvanillylmandelic acid, and 0.012 mu mol l-1 for 5-hydroxyindole-3-acetic acid (calculated from areas), respectively.
Determination of 5-hydroxyindole-3-acetic acid using Flow Injection Analysis with Electrochemical Detection
Makrlíková, Anna ; Matysik, F.-M. ; Navrátil, Tomáš ; Barek, J. ; Vyskočil, V.
Tumour biomarker, 5-hydroxyindole-3-acetic acid, has been determined at screen-printed carbon electrodes using flow injection analysis with amperometric detection. Britton-Robinson buffer (0.04 mol-l-1 , pH 2.0) was used as an optimum carrier solution.\nDependence of the peak current on the analyte concentration was linear in the whole tested\nconcentration range (from 0.5 to 100 mikromol-l-1) with limits of detection 0.033 mikromol-l-1 \n(calculated from peak heighst) and 0.012 mikromol-l-1 (calculated from peak areas).