Žádný přesný výsledek pro Koudelka_ml., Petr nebyl nalezen, zkusme místo něj použít Koudelka ml Petr ...
Národní úložiště šedé literatury Nalezeno 14 záznamů.  1 - 10další  přejít na záznam: Hledání trvalo 0.04 vteřin. 
Laboratory X-ray imaging in material sciences
Koudelka_ml., Petr ; Kytýř, Daniel ; Jiroušek, O.
In recent decades, X-ray imaging and computed (micro)tomography (XCT) in particular have become common tools for volumetric inspection, visualization, and analysis of internal structure in materials from various fields [1]. In this lecture, we will explore various applications of laboratory X-ray imaging chains utilizing the combination of tomographical imaging with mechanical, thermal, or chemical loading of the irradiated sample in a so-called time-resolved imaging allowing for unprecedented insight into different phenomena driving fundamental processes encountered in various fields of material science. We will show that failure processes in engineering or geological materials [2] can be thoroughly studied by synergy of information from radiographical imaging and other methods including acoustic emission detection and optical measurements via high-speed visible-spectrum and thermal-imaging cameras, where the radiography provides important spatial information regarding deformation processes evolving within the tested samples that could not be obtained otherwise. The state-of-the-art the laboratory based imaging chains for investigation of dynamic response of materials under loading will be also discussed including high speed X-ray radiography utilizing a powerful X-ray source during high velocity impact as an approach suitable for inspection of an impacted sample. As an alternative to both conventional high-power sources and accelerator facilities, capabilities of a flash X-ray system developed primarily for in-situ ballistics research providing very short bursts of an extremely powerful intermittent X-ray radiation with a typical duration of dozens of nanoseconds will be shown.
Computed tomography system with strict real-time synchronization for in-situ 3D analysis of periodically vibrating objects
Rada, Václav ; Fíla, Tomáš ; Zlámal, Petr ; Koudelka_ml., Petr ; Šleichrt, Jan ; Macháček, Michael ; Vavřík, Daniel ; Kytýř, Daniel
In the contribution, we present a laboratory system capable of X-ray computed tomography (XCT) scanning of an periodically moving or oscillating object. The system is an in-house developed XCT setup with electromagnetic voice coil actuator mounted on top of the rotary stage of the setup. The strict synchronization of the components, the rotary stage, the electromagnetic actuator movement and the detector readout is accomplished with use of the detector hardware trigger and hard real-time Linux operating system. Cylindrical sample manufactured from epoxy resin with metal particles to enable movement tracking is scanned in a stationary position and during periodical movement induced by the vibration stage. The volumetric data of the scans is compared and the results of this contribution represent an important step towards identification of defects through modal analysis of in-situ harmonically vibrating object.
Tomographic investigation of the sandstone fracture toughness
Vavřík, Daniel ; Beneš, Pavel ; Fíla, Tomáš ; Koudelka_ml., Petr ; Kumpová, Ivana ; Vavro, Martin
It is well known that the measured values of the fracture toughness of quasi brittle materials are influenced by material heterogeneity, dimensions, boundary conditions, and unequal tension and compression properties. Standard testing methods supposing isotropic material, in contrary the quasi-brittle materials differ from this theoretical expectation, therefore this approach may fail. The authors present Local Fracture Toughness Testing (LFTT) method to overcome this obstacle. LFFT based on a complex methodology using a series of tomographic reconstructions recorded during specimen loading is calculated independently of the outside boundary conditions.
Multi-channel control system for in-situ laboratory loading devices
Rada, Václav ; Fíla, Tomáš ; Zlámal, Petr ; Kytýř, Daniel ; Koudelka_ml., P.
In recent years, open-source applications have replaced proprietary software in many fields. Especially open-source software tools based on Linux operating system have wide range of utilization. In terms of CNC solutions, an open-source system LinuxCNC can be used. However, the LinuxCNC control software and the graphical user interface (GUI) could be developed only on top of Hardware Abstraction Layer. Nevertheless, the LinuxCNC community provided Python Interface, which allows for controlling CNC machine using Python programming language, therefore whole control software can be developed in Python. The paper focuses on a development of a multi-process control software mainly for in-house developed loading devices operated at our institute. The software tool is based on the LinuxCNC Python Interface and Qt framework, which gives the software an ability to be modular and effectively adapted for various devices.
Instrumentation of four-point bending test during 4D computed tomography
Kytýř, Daniel ; Fíla, Tomáš ; Koudelka_ml., Petr ; Kumpová, Ivana ; Vopálenský, Michal ; Vavro, Leona ; Vavro, Martin
High-resolution time-lapse micro-focus X-ray computed tomography is an effective method for investigation of deformation processes on volumetric basis including fracture propagation characteristics of non-homogeneous materials subjected to mechanical loading. This experimental method requires implementation of specifically designed loading devices to X-ray imaging setups. In case of bending tests, our background research showed that no commercial solution allowing for reliable investigation of so called fracture process zone in quasi-brittle materials is currently available. Thus, this paper is focused on description of recently developed in-situ four-point bending loading device and its instrumentation for testing of quasi-brittle materials. Proof of concept together with the pilot experiments were successfully performed in a CT scanner TORATOM. Based on results of the pilot experiments, we demonstrate that crack development and propagation in a quasi-brittle material can be successfully observed in 3D using high resolution 4D micro-CT under loading.
Utilization of image and signal processing techniques for assessment of built heritage condition
Koudelka_ml., Petr ; Koudelková, Veronika ; Doktor, Tomáš ; Kumpová, Ivana ; Kytýř, Daniel ; Valach, Jaroslav
Historical buildings represent invaluable heritage from the past and therefore their protection is a very important task. Assessment of their condition must not cause damage accumulation thus the least possible volume removed from the structure is essential. As many historical buildings in the Czech Republic are built using sandstone that can be considered as a typical heterogeneous system, statistical signal processing is a promising approach for determination of the representative volume element (RVE) dimensions. Such calculations can be carried out on the domain of logical arrays representing binary images of the materials microstructure. This paper deals with processing of image data obtained using SEM-BSE and high resolution flatbed scanner for determination of RVE dimensions. Advanced image processing techniques are employed and results from calculation using grayscale data are presented and compared with results calculated on the basis of color input images.
Deformation behaviour of gellan gum based artificial bone structures under simulated physiological conditions
Krčmářová, N. ; Šleichrt, J. ; Fíla, Tomáš ; Koudelka_ml., Petr ; Kytýř, Daniel
The paper deals with investigation of deformation behaviour of gellan gum (GG) based\nstructures prepared for regenerative medicine purposes. Investigated material was synthesized as porous spongy-like scaffold reinforced by bioactive glass (BAG) nano-particles in different concentrations. Deformation behavior was obtained employing custom designed experimental setup. This device equipped with bioreactor chamber allows to test the delivered samples under simulated physiological conditions with controlled flow and temperature. Cylindrical samples were subjected to uniaxial quasi-static loading in tension and compression. Material properties of plain scaffold buffered by 50 wt% and 70 wt% BAG were derived from a set of tensile and compression tests. The results are represented in form of stress-strain curves calculated from the acquired force and displacement data.
Mechanical properties of 3D auxetic structures produced by additive manufacturing
Jiroušek, O. ; Koudelka_ml., Petr ; Fíla, Tomáš
Three distinct auxetic structures were produced by direct 3D printing based on parametric CAD models. Mechanical properties of the structures were established by static compression tests where strain fields on the surface of the specimens was measured by non-contact optical method. Parametric finite element (FE) model of each structure was then subjected to a virtual compression test and mechanical properties obtained from the FE simulations were compared to the experimentally assessed values. After verification, the parametric FE models were used to establish relationships between various design parameters (porosity, rod thickness, internal angles, etc.) and overall mechanical properties (particularly stiffness).
Determination of drift distortion in SEM micrographs acquired at different magnifications and acquisition times
Petráňová, Veronika ; Koudelka_ml., Petr ; Valach, Jaroslav
In the experimental mechanics wide variety of optical methods including measurement of deformation at reduced length scales using combination of computer vision and scanning electron microscopy (SEM) have been recently applied. One of suitable methods for in-plane measurement of displacements and deformations in the micrographs obtained by SEM is the 2D digital image correlation. In contrast to images obtained in visible spectrum by classical optical devices temporally-varying distortions known as drift distortion are present in the SEM micrographs. These distortions are caused by positional errors of electron beam during scanning process. Magnitude of this effect decreases with higher conductivity of the sample and is also influenced by magnification and scanning time. For this purpose measurement of distortion was performed on a series of micrographs of conductive samples acquired at different magnifications and acquisition times. Surface of each sample was covered with liquid silver to ensure adequate contrast pattern necessary for determination of distortion’s magnitude and distortion magnitudes were assessed.
On the X-ray micro-tomography measurements of biological samples under compressive loading
Fíla, T. ; Kumpová, Ivana ; Zlámal, Petr ; Kytýř, Daniel ; Koudelka_ml., Petr ; Doktor, Tomáš ; Jiroušek, Ondřej
In this paper, compact loading device for micro-CT measurements under applied load was used in a series of instrumented compressive test of bone sample. Tested bone samples were loaded in several deformation steps and micro-CT scanning was carried out in each step. Reconstructed three-dimensional data of intact bone sample were used to develop 3D model of the specimen. Data from each deformation step were processed by DVC method for identification of displacement and strain fields and thus for evaluation of deformation response of human trabecular bone sample.

Národní úložiště šedé literatury : Nalezeno 14 záznamů.   1 - 10další  přejít na záznam:
Viz též: podobná jména autorů
2 Koudelka_ml., P.
Chcete být upozorněni, pokud se objeví nové záznamy odpovídající tomuto dotazu?
Přihlásit se k odběru RSS.