Název: On the X-ray micro-tomography measurements of biological samples under compressive loading
Autoři: Fíla, T. ; Kumpová, Ivana ; Zlámal, Petr ; Kytýř, Daniel ; Koudelka_ml., Petr ; Doktor, Tomáš ; Jiroušek, Ondřej
Typ dokumentu: Příspěvky z konference
Konference/Akce: Youth symposium on experimental solid mechanics /13./, Děčín (CZ), 2014-06-29 / 2014-07-02
Rok: 2014
Jazyk: eng
Abstrakt: In this paper, compact loading device for micro-CT measurements under applied load was used in a series of instrumented compressive test of bone sample. Tested bone samples were loaded in several deformation steps and micro-CT scanning was carried out in each step. Reconstructed three-dimensional data of intact bone sample were used to develop 3D model of the specimen. Data from each deformation step were processed by DVC method for identification of displacement and strain fields and thus for evaluation of deformation response of human trabecular bone sample.
Klíčová slova: compressive test; finite element modelling; medical imaging; micro-tomography; trabecular bone
Číslo projektu: GAP105/10/2305 (CEP)
Poskytovatel projektu: GA ČR
Zdrojový dokument: Proceedings of XIIIth youth symposium on experimental solid mechanics, ISBN 978-80-01-05556-4

Instituce: Ústav teoretické a aplikované mechaniky AV ČR (web)
Informace o dostupnosti dokumentu: Dokument je dostupný na externích webových stránkách.
Externí umístění souboru: http://www.itam.cas.cz/ysesm2014/proceedings/id_40_ysesm2014_proceedings.pdf
Původní záznam: http://hdl.handle.net/11104/0236189

Trvalý odkaz NUŠL: http://www.nusl.cz/ntk/nusl-175205


Záznam je zařazen do těchto sbírek:
Věda a výzkum > AV ČR > Ústav teoretické a aplikované mechaniky
Konferenční materiály > Příspěvky z konference
 Záznam vytvořen dne 2014-09-18, naposledy upraven 2023-12-06.